Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Switching power at 400 V
-kW
Version as main switch
Yes
Version as maintenance-/service switch
No
Version as safety switch
No
Version as reversing switch
No
Version as emergency stop installation
Yes
Number of switches
1
Suitable for front mounting centre
Yes
Suitable for distribution board installation
No
Rated operation power at AC-3, 400 V
7.5kW
Number of poles
3
Rated operating voltage
690 - 690V
Rated permanent current at AC-21, 400 V
32A
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
32A
Device construction
Built-in device fixed built-in technique
Interlockable
Yes
Rated operation power at AC-23, 400 V
11kW
Motor drive integrated
No
Number of auxiliary contacts as normally open contact
0
Max. rated operation voltage Ue AC
690V
Conditioned rated short-circuit current Iq
10kA
Rated permanent current at AC-23, 400 V
21.8A
Rated short-time withstand current lcw
0.384kA
Number of auxiliary contacts as change-over contact
0
Motor drive optional
No
Suitable for floor mounting
No
Suitable for front mounting 4-hole
No
Suitable for intermediate mounting
No
Voltage release optional
No
Colour control element
Red
Type of control element
Short thumb-grip
Degree of protection (IP), front side
IP65
Type of electrical connection of main circuit
Screw connection
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
VCD1
Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Switching power at 400 V
-kW
Version as main switch
Version as maintenance-/service switch
Version as safety switch
Version as reversing switch
Version as emergency stop installation
Number of switches
1
Suitable for front mounting centre
Suitable for distribution board installation
Rated operation power at AC-3, 400 V
7.5kW
Number of poles
3
Rated operating voltage
690 .. 690V
Rated permanent current at AC-21, 400 V
32A
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
32A
Device construction
Built-in device fixed built-in technique
Interlockable
Rated operation power at AC-23, 400 V
11kW
Motor drive integrated
Number of auxiliary contacts as normally open contact
0
Max. rated operation voltage Ue AC
690V
Conditioned rated short-circuit current Iq
10kA
Rated permanent current at AC-23, 400 V
21.8A
Rated short-time withstand current lcw
0.384kA
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Suitable for floor mounting
Suitable for front mounting 4-hole
Suitable for intermediate mounting
Voltage release optional
Colour control element
Red
Type of control element
Short thumb-grip
Degree of protection (IP), front side
IP65
Type of electrical connection of main circuit
Screw connection
From same serie