- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Switching power at 400 V
-kW
Version as maintenance-/service switch
No
Version as main switch
Yes
Version as safety switch
No
Number of switches
1
Rated permanent current at AC-23, 400 V
11A
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-21, 400 V
20A
Rated operating voltage
690 - 690V
Conditioned rated short-circuit current Iq
10kA
Rated operation power at AC-3, 400 V
4kW
Rated permanent current Iu
20A
Rated operation power at AC-23, 400 V
5.5kW
Rated short-time withstand current lcw
0.3kA
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Suitable for floor mounting
No
Motor drive integrated
No
Suitable for front mounting 4-hole
No
Version as reversing switch
No
Device construction
Built-in device fixed built-in technique
Voltage release optional
No
Suitable for front mounting centre
Yes
Suitable for intermediate mounting
No
Colour control element
Red
Type of control element
Short thumb-grip
Suitable for distribution board installation
No
Version as emergency stop installation
Yes
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP65
Interlockable
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
VCD01
![Main Product Image](https://assets.aleta.hr/300x300/3c52b1bd-01ea-46e5-8de6-6dd02ab36632_optimized.webp)
Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Switching power at 400 V
-kW
Version as maintenance-/service switch
Version as main switch
Version as safety switch
Number of switches
1
Rated permanent current at AC-23, 400 V
11A
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-21, 400 V
20A
Rated operating voltage
690 .. 690V
Conditioned rated short-circuit current Iq
10kA
Rated operation power at AC-3, 400 V
4kW
Rated permanent current Iu
20A
Rated operation power at AC-23, 400 V
5.5kW
Rated short-time withstand current lcw
0.3kA
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Suitable for floor mounting
Motor drive integrated
Suitable for front mounting 4-hole
Version as reversing switch
Device construction
Built-in device fixed built-in technique
Voltage release optional
Suitable for front mounting centre
Suitable for intermediate mounting
Colour control element
Red
Type of control element
Short thumb-grip
Suitable for distribution board installation
Version as emergency stop installation
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP65
Interlockable