Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Switching power at 400 V
-kW
Version as reversing switch
No
Version as main switch
Yes
Rated operation power at AC-3, 400 V
5.5kW
Version as emergency stop installation
Yes
Rated operation power at AC-23, 400 V
7.5kW
Number of poles
3
Rated operating voltage
690 - 690V
Rated permanent current Iu
25A
Voltage release optional
No
Rated short-time withstand current lcw
0.3kA
Motor drive integrated
No
Device construction
Built-in device fixed built-in technique
Version as safety switch
No
Rated permanent current at AC-21, 400 V
25A
Suitable for front mounting centre
Yes
Number of auxiliary contacts as normally closed contact
0
Number of switches
1
Conditioned rated short-circuit current Iq
10kA
Motor drive optional
No
Suitable for front mounting 4-hole
No
Version as maintenance-/service switch
No
Number of auxiliary contacts as normally open contact
0
Interlockable
Yes
Number of auxiliary contacts as change-over contact
0
Suitable for floor mounting
No
Rated permanent current at AC-23, 400 V
14.5A
Max. rated operation voltage Ue AC
690V
Type of electrical connection of main circuit
Screw connection
Suitable for distribution board installation
No
Colour control element
Red
Type of control element
Short thumb-grip
Suitable for intermediate mounting
No
Degree of protection (IP), front side
IP65
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
VCD0
![Main Product Image](https://assets.aleta.hr/300x300/3c52b1bd-01ea-46e5-8de6-6dd02ab36632_optimized.webp)
Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Switching power at 400 V
-kW
Version as reversing switch
Version as main switch
Rated operation power at AC-3, 400 V
5.5kW
Version as emergency stop installation
Rated operation power at AC-23, 400 V
7.5kW
Number of poles
3
Rated operating voltage
690 .. 690V
Rated permanent current Iu
25A
Voltage release optional
Rated short-time withstand current lcw
0.3kA
Motor drive integrated
Device construction
Built-in device fixed built-in technique
Version as safety switch
Rated permanent current at AC-21, 400 V
25A
Suitable for front mounting centre
Number of auxiliary contacts as normally closed contact
0
Number of switches
1
Conditioned rated short-circuit current Iq
10kA
Motor drive optional
Suitable for front mounting 4-hole
Version as maintenance-/service switch
Number of auxiliary contacts as normally open contact
0
Interlockable
Number of auxiliary contacts as change-over contact
0
Suitable for floor mounting
Rated permanent current at AC-23, 400 V
14.5A
Max. rated operation voltage Ue AC
690V
Type of electrical connection of main circuit
Screw connection
Suitable for distribution board installation
Colour control element
Red
Type of control element
Short thumb-grip
Suitable for intermediate mounting
Degree of protection (IP), front side
IP65