Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Switching power at 400 V
-kW
Version as maintenance-/service switch
No
Version as safety switch
No
Version as main switch
Yes
Number of switches
1
Version as emergency stop installation
Yes
Version as reversing switch
No
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
29A
Rated short-time withstand current lcw
0.48kA
Rated permanent current at AC-21, 400 V
40A
Rated operation power at AC-23, 400 V
15kW
Rated operating voltage
690 - 690V
Rated permanent current Iu
40A
Conditioned rated short-circuit current Iq
10kA
Number of poles
3
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Number of auxiliary contacts as normally closed contact
0
Voltage release optional
No
Suitable for front mounting 4-hole
Yes
Suitable for floor mounting
No
Rated operation power at AC-3, 400 V
11kW
Device construction
Built-in device fixed built-in technique
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Suitable for front mounting centre
No
Type of electrical connection of main circuit
Screw connection
Interlockable
Yes
Type of control element
Door coupling rotary drive
Motor drive optional
No
Degree of protection (IP), front side
IP65
Number of auxiliary contacts as change-over contact
0
Colour control element
Red
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
VCCF2
Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Switching power at 400 V
-kW
Version as maintenance-/service switch
Version as safety switch
Version as main switch
Number of switches
1
Version as emergency stop installation
Version as reversing switch
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
29A
Rated short-time withstand current lcw
0.48kA
Rated permanent current at AC-21, 400 V
40A
Rated operation power at AC-23, 400 V
15kW
Rated operating voltage
690 .. 690V
Rated permanent current Iu
40A
Conditioned rated short-circuit current Iq
10kA
Number of poles
3
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Number of auxiliary contacts as normally closed contact
0
Voltage release optional
Suitable for front mounting 4-hole
Suitable for floor mounting
Rated operation power at AC-3, 400 V
11kW
Device construction
Built-in device fixed built-in technique
Suitable for distribution board installation
Suitable for intermediate mounting
Suitable for front mounting centre
Type of electrical connection of main circuit
Screw connection
Interlockable
Type of control element
Door coupling rotary drive
Motor drive optional
Degree of protection (IP), front side
IP65
Number of auxiliary contacts as change-over contact
0
Colour control element
Red
From same serie