Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Type of control element
None
Switching power at 400 V
-kW
Version as main switch
No
Version as emergency stop installation
No
Number of switches
1
Rated operating voltage
690 - 690V
Version as safety switch
No
Version as reversing switch
No
Rated permanent current Iu
63A
Rated permanent current at AC-21, 400 V
63A
Max. rated operation voltage Ue AC
690V
Version as maintenance-/service switch
No
Rated operation power at AC-23, 400 V
15kW
Number of poles
3
Rated operation power at AC-3, 400 V
18.5kW
Rated short-time withstand current lcw
0.756kA
Motor drive optional
No
Conditioned rated short-circuit current Iq
10kA
Number of auxiliary contacts as normally open contact
0
Voltage release optional
No
Suitable for floor mounting
No
Suitable for front mounting 4-hole
Yes
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Motor drive integrated
No
Type of electrical connection of main circuit
Screw connection
Interlockable
No
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Rated permanent current at AC-23, 400 V
41.5A
Suitable for front mounting centre
Yes
Degree of protection (IP), front side
IP20
Number of auxiliary contacts as normally closed contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
V3
Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Type of control element
None
Switching power at 400 V
-kW
Version as main switch
Version as emergency stop installation
Number of switches
1
Rated operating voltage
690 .. 690V
Version as safety switch
Version as reversing switch
Rated permanent current Iu
63A
Rated permanent current at AC-21, 400 V
63A
Max. rated operation voltage Ue AC
690V
Version as maintenance-/service switch
Rated operation power at AC-23, 400 V
15kW
Number of poles
3
Rated operation power at AC-3, 400 V
18.5kW
Rated short-time withstand current lcw
0.756kA
Motor drive optional
Conditioned rated short-circuit current Iq
10kA
Number of auxiliary contacts as normally open contact
0
Voltage release optional
Suitable for floor mounting
Suitable for front mounting 4-hole
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Motor drive integrated
Type of electrical connection of main circuit
Screw connection
Interlockable
Suitable for distribution board installation
Suitable for intermediate mounting
Rated permanent current at AC-23, 400 V
41.5A
Suitable for front mounting centre
Degree of protection (IP), front side
IP20
Number of auxiliary contacts as normally closed contact