Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Type of control element
None
Switching power at 400 V
-kW
Version as main switch
No
Version as emergency stop installation
No
Version as safety switch
No
Version as maintenance-/service switch
No
Number of switches
1
Rated permanent current Iu
40A
Version as reversing switch
No
Rated permanent current at AC-23, 400 V
29A
Rated operating voltage
690 - 690V
Rated operation power at AC-3, 400 V
11kW
Rated short-time withstand current lcw
0.48kA
Max. rated operation voltage Ue AC
690V
Number of auxiliary contacts as normally open contact
0
Rated operation power at AC-23, 400 V
15kW
Number of poles
3
Rated permanent current at AC-21, 400 V
40A
Suitable for front mounting 4-hole
Yes
Motor drive optional
No
Suitable for intermediate mounting
No
Voltage release optional
No
Suitable for front mounting centre
Yes
Suitable for floor mounting
No
Degree of protection (IP), front side
IP20
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Interlockable
No
Conditioned rated short-circuit current Iq
10kA
Device construction
Built-in device fixed built-in technique
Suitable for distribution board installation
No
Number of auxiliary contacts as change-over contact
0
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
V2
Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Type of control element
None
Switching power at 400 V
-kW
Version as main switch
Version as emergency stop installation
Version as safety switch
Version as maintenance-/service switch
Number of switches
1
Rated permanent current Iu
40A
Version as reversing switch
Rated permanent current at AC-23, 400 V
29A
Rated operating voltage
690 .. 690V
Rated operation power at AC-3, 400 V
11kW
Rated short-time withstand current lcw
0.48kA
Max. rated operation voltage Ue AC
690V
Number of auxiliary contacts as normally open contact
0
Rated operation power at AC-23, 400 V
15kW
Number of poles
3
Rated permanent current at AC-21, 400 V
40A
Suitable for front mounting 4-hole
Motor drive optional
Suitable for intermediate mounting
Voltage release optional
Suitable for front mounting centre
Suitable for floor mounting
Degree of protection (IP), front side
IP20
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Interlockable
Conditioned rated short-circuit current Iq
10kA
Device construction
Built-in device fixed built-in technique
Suitable for distribution board installation
Number of auxiliary contacts as change-over contact
0
Motor drive integrated
From same serie