Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Type of control element
None
Switching power at 400 V
-kW
Version as main switch
No
Version as maintenance-/service switch
No
Version as reversing switch
No
Version as safety switch
No
Number of switches
1
Rated operating voltage
690 - 690V
Version as emergency stop installation
No
Rated permanent current at AC-23, 400 V
8.1A
Rated permanent current at AC-21, 400 V
12A
Rated permanent current Iu
12A
Max. rated operation voltage Ue AC
690V
Rated operation power at AC-23, 400 V
4kW
Rated operation power at AC-3, 400 V
3kW
Rated short-time withstand current lcw
0.3kA
Number of poles
3
Conditioned rated short-circuit current Iq
10kA
Number of auxiliary contacts as change-over contact
0
Motor drive optional
No
Motor drive integrated
No
Voltage release optional
No
Suitable for floor mounting
No
Suitable for front mounting 4-hole
Yes
Number of auxiliary contacts as normally closed contact
0
Suitable for front mounting centre
Yes
Suitable for intermediate mounting
No
Number of auxiliary contacts as normally open contact
0
Suitable for distribution board installation
No
Interlockable
No
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP20
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
V02
Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Type of control element
None
Switching power at 400 V
-kW
Version as main switch
Version as maintenance-/service switch
Version as reversing switch
Version as safety switch
Number of switches
1
Rated operating voltage
690 .. 690V
Version as emergency stop installation
Rated permanent current at AC-23, 400 V
8.1A
Rated permanent current at AC-21, 400 V
12A
Rated permanent current Iu
12A
Max. rated operation voltage Ue AC
690V
Rated operation power at AC-23, 400 V
4kW
Rated operation power at AC-3, 400 V
3kW
Rated short-time withstand current lcw
0.3kA
Number of poles
3
Conditioned rated short-circuit current Iq
10kA
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Motor drive integrated
Voltage release optional
Suitable for floor mounting
Suitable for front mounting 4-hole
Number of auxiliary contacts as normally closed contact
0
Suitable for front mounting centre
Suitable for intermediate mounting
Number of auxiliary contacts as normally open contact
0
Suitable for distribution board installation
Interlockable
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP20
From same serie