Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
0 - 0V
Supply voltage AC 60 Hz
0 - 0V
Supply voltage DC
19.2 - 28.8V
Max. number of time switches
0
Model
Compact
Number of interfaces PROFINET
0
Processing time (1K, binary operation)
0.022ms
Number of relay outputs
0
With optical interface
No
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-232
2
Number of HW-interfaces USB
1
Number of analogue inputs
0
Number of HW-interfaces RS-485
2
Supporting protocol for TCP/IP
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for Data-Highway
No
Number of HW-interfaces industrial Ethernet
1
Voltage type of supply voltage
DC
Supporting protocol for ASI
No
Supporting protocol for CAN
No
Supporting protocol for Modbus
Yes
Number of HW-interfaces Wireless
0
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Number of analogue outputs
0
Number of digital inputs
14
Number of digital outputs
10
Number of HW-interfaces other
0
Number of HW-interfaces RS-422
0
Supporting protocol for LON
No
Supporting protocol for PROFIBUS
No
Supporting protocol for KNX
No
Supporting protocol for DeviceNet
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for PROFIsafe
No
Supporting protocol for SERCOS
No
Supporting protocol for other bus systems
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for IEC 61850 Ethernet
No
Supporting protocol for DeviceNet Safety
No
Radio standard Wi-Fi 802.11
No
Supporting protocol for IEC 60870
No
Radio standard Bluetooth
No
Supporting protocol for DNP3
No
Radio standard GSM
No
Supporting protocol for INTERBUS-Safety
No
Long-Term Evolution (LTE)
No
Radio standard GPRS
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for AS-Interface Safety at Work
No
IO link master
No
Redundancy
No
With display
No
System accessory
No
Memory size
64000kByte
Type of memory
NVRAM
Additional program memory possible
Yes
Rail mounting possible
Yes
Wall mounting/direct mounting
Yes
SIL according to IEC 61508
None
Front built-in possible
No
Suitable for safety functions
No
Rack-assembly possible
No
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Explosion safety category for gas
None
Height
90mm
Width
150mm
Explosion safety category for dust
None
Depth
95mm
Appendant operation agent (Ex ib)
No
Radio standard UMTS
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
TM241CE24T

Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
0 .. 0V
Supply voltage AC 60 Hz
0 .. 0V
Supply voltage DC
19.2 .. 28.8V
Max. number of time switches
0
Model
Compact
Number of interfaces PROFINET
0
Processing time (1K, binary operation)
0.022ms
Number of relay outputs
0
With optical interface
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-232
2
Number of HW-interfaces USB
1
Number of analogue inputs
0
Number of HW-interfaces RS-485
2
Supporting protocol for TCP/IP
Supporting protocol for INTERBUS
Supporting protocol for Data-Highway
Number of HW-interfaces industrial Ethernet
1
Voltage type of supply voltage
DC
Supporting protocol for ASI
Supporting protocol for CAN
Supporting protocol for Modbus
Number of HW-interfaces Wireless
0
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Number of analogue outputs
0
Number of digital inputs
14
Number of digital outputs
10
Number of HW-interfaces other
0
Number of HW-interfaces RS-422
0
Supporting protocol for LON
Supporting protocol for PROFIBUS
Supporting protocol for KNX
Supporting protocol for DeviceNet
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for PROFIsafe
Supporting protocol for SERCOS
Supporting protocol for other bus systems
Supporting protocol for Foundation Fieldbus
Supporting protocol for IEC 61850 Ethernet
Supporting protocol for DeviceNet Safety
Radio standard Wi-Fi 802.11
Supporting protocol for IEC 60870
Radio standard Bluetooth
Supporting protocol for DNP3
Radio standard GSM
Supporting protocol for INTERBUS-Safety
Long-Term Evolution (LTE)
Radio standard GPRS
Supporting protocol for SafetyBUS p
Supporting protocol for AS-Interface Safety at Work
IO link master
Redundancy
With display
System accessory
Memory size
64000kByte
Type of memory
NVRAM
Additional program memory possible
Rail mounting possible
Wall mounting/direct mounting
SIL according to IEC 61508
None
Front built-in possible
Suitable for safety functions
Rack-assembly possible
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
Explosion safety category for gas
None
Height
90mm
Width
150mm
Explosion safety category for dust
None
Depth
95mm
Appendant operation agent (Ex ib)
Radio standard UMTS
From same serie
We use cookies to enhance your experience.