Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
0 - 0V
Supply voltage AC 60 Hz
0 - 0V
Supply voltage DC
19.2 - 28.8V
Voltage type of supply voltage
DC
Number of relay outputs
0
Max. number of time switches
255
Processing time (1K, binary operation)
0.2ms
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
0
Model
Compact
Number of HW-interfaces RS-232
2
Number of HW-interfaces other
0
Number of HW-interfaces RS-485
2
Number of HW-interfaces parallel
0
Number of analogue inputs
2
Number of HW-interfaces USB
1
With optical interface
No
Number of HW-interfaces RS-422
0
Supporting protocol for Modbus
Yes
Number of analogue outputs
0
Number of digital inputs
8
Supporting protocol for PROFIBUS
No
Supporting protocol for DeviceNet
No
Supporting protocol for ASI
No
Supporting protocol for CAN
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SUCONET
No
Supporting protocol for KNX
No
Number of HW-interfaces Wireless
0
Supporting protocol for Data-Highway
No
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS
No
Number of digital outputs
8
Long-Term Evolution (LTE)
No
Supporting protocol for TCP/IP
No
IO link master
No
System accessory
No
Redundancy
No
Type of memory
RAM
Memory size
512kByte
Additional program memory possible
Yes
Rail mounting possible
Yes
Wall mounting/direct mounting
Yes
Front built-in possible
No
Rack-assembly possible
No
Suitable for safety functions
No
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
No
Performance level according to EN ISO 13849-1
None
Explosion safety category for gas
None
Appendant operation agent (Ex ib)
No
Width
70mm
Explosion safety category for dust
None
Height
102mm
Depth
85mm
Supporting protocol for PROFINET IO
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for IEC 60870
No
Supporting protocol for other bus systems
No
Supporting protocol for IEC 61850 Ethernet
No
Radio standard Bluetooth
No
Supporting protocol for DNP3
No
Radio standard Wi-Fi 802.11
No
Radio standard GPRS
No
Radio standard UMTS
No
Radio standard GSM
No
With display
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
TM221M16TG

Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
0 .. 0V
Supply voltage AC 60 Hz
0 .. 0V
Supply voltage DC
19.2 .. 28.8V
Voltage type of supply voltage
DC
Number of relay outputs
0
Max. number of time switches
255
Processing time (1K, binary operation)
0.2ms
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
0
Model
Compact
Number of HW-interfaces RS-232
2
Number of HW-interfaces other
0
Number of HW-interfaces RS-485
2
Number of HW-interfaces parallel
0
Number of analogue inputs
2
Number of HW-interfaces USB
1
With optical interface
Number of HW-interfaces RS-422
0
Supporting protocol for Modbus
Number of analogue outputs
0
Number of digital inputs
8
Supporting protocol for PROFIBUS
Supporting protocol for DeviceNet
Supporting protocol for ASI
Supporting protocol for CAN
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for SUCONET
Supporting protocol for KNX
Number of HW-interfaces Wireless
0
Supporting protocol for Data-Highway
Supporting protocol for SERCOS
Supporting protocol for INTERBUS
Number of digital outputs
8
Long-Term Evolution (LTE)
Supporting protocol for TCP/IP
IO link master
System accessory
Redundancy
Type of memory
RAM
Memory size
512kByte
Additional program memory possible
Rail mounting possible
Wall mounting/direct mounting
Front built-in possible
Rack-assembly possible
Suitable for safety functions
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
Performance level according to EN ISO 13849-1
None
Explosion safety category for gas
None
Appendant operation agent (Ex ib)
Width
70mm
Explosion safety category for dust
None
Height
102mm
Depth
85mm
Supporting protocol for PROFINET IO
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for IEC 60870
Supporting protocol for other bus systems
Supporting protocol for IEC 61850 Ethernet
Radio standard Bluetooth
Supporting protocol for DNP3
Radio standard Wi-Fi 802.11
Radio standard GPRS
Radio standard UMTS
Radio standard GSM
With display
From same serie
We use cookies to enhance your experience.