

Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
0 - 0V
Supply voltage AC 60 Hz
0 - 0V
Voltage type of supply voltage
DC
Model
Compact
Number of relay outputs
8
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
2
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Max. number of time switches
255
Number of HW-interfaces USB
1
Number of HW-interfaces parallel
0
Processing time (1K, binary operation)
0.2ms
Number of HW-interfaces RS-232
2
Number of analogue outputs
0
Number of HW-interfaces other
0
Number of analogue inputs
2
Number of digital inputs
8
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
With optical interface
No
Supporting protocol for SUCONET
No
Supporting protocol for Data-Highway
No
Number of HW-interfaces Wireless
0
Supporting protocol for Modbus
Yes
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFIBUS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for KNX
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for EtherNet/IP
No
Number of digital outputs
8
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for TCP/IP
No
Supporting protocol for ASI
No
Supporting protocol for LON
No
Supporting protocol for DeviceNet
No
Supply voltage DC
19.2 - 28.8V
Long-Term Evolution (LTE)
No
IO link master
No
System accessory
No
Supporting protocol for SafetyBUS p
No
Redundancy
No
With display
No
Type of memory
RAM
Memory size
512kByte
Supporting protocol for IEC 61850 Ethernet
No
Additional program memory possible
Yes
Rail mounting possible
Yes
Supporting protocol for other bus systems
No
Supporting protocol for DNP3
No
Supporting protocol for PROFIsafe
No
Supporting protocol for IEC 60870
No
Wall mounting/direct mounting
Yes
Rack-assembly possible
No
Front built-in possible
No
SIL according to IEC 61508
None
Suitable for safety functions
No
Appendant operation agent (Ex ia)
No
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ib)
No
Radio standard Wi-Fi 802.11
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
70mm
Height
102mm
Depth
85mm
Radio standard GPRS
No
Radio standard Bluetooth
No
Radio standard UMTS
No
Radio standard GSM
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
TM221M16RG

Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
0 .. 0V
Supply voltage AC 60 Hz
0 .. 0V
Voltage type of supply voltage
DC
Model
Compact
Number of relay outputs
8
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
2
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Max. number of time switches
255
Number of HW-interfaces USB
1
Number of HW-interfaces parallel
0
Processing time (1K, binary operation)
0.2ms
Number of HW-interfaces RS-232
2
Number of analogue outputs
0
Number of HW-interfaces other
0
Number of analogue inputs
2
Number of digital inputs
8
Supporting protocol for CAN
Supporting protocol for INTERBUS
With optical interface
Supporting protocol for SUCONET
Supporting protocol for Data-Highway
Number of HW-interfaces Wireless
0
Supporting protocol for Modbus
Supporting protocol for PROFINET IO
Supporting protocol for PROFIBUS
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Supporting protocol for KNX
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Number of digital outputs
8
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET CBA
Supporting protocol for TCP/IP
Supporting protocol for ASI
Supporting protocol for LON
Supporting protocol for DeviceNet
Supply voltage DC
19.2 .. 28.8V
Long-Term Evolution (LTE)
IO link master
System accessory
Supporting protocol for SafetyBUS p
Redundancy
With display
Type of memory
RAM
Memory size
512kByte
Supporting protocol for IEC 61850 Ethernet
Additional program memory possible
Rail mounting possible
Supporting protocol for other bus systems
Supporting protocol for DNP3
Supporting protocol for PROFIsafe
Supporting protocol for IEC 60870
Wall mounting/direct mounting
Rack-assembly possible
Front built-in possible
SIL according to IEC 61508
None
Suitable for safety functions
Appendant operation agent (Ex ia)
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ib)
Radio standard Wi-Fi 802.11
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
70mm
Height
102mm
Depth
85mm
Radio standard GPRS
Radio standard Bluetooth
Radio standard UMTS
Radio standard GSM
From same serie
We use cookies to enhance your experience.