Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- - -V
Supply voltage AC 60 Hz
- - -V
Supply voltage DC
24 - 24V
Number of digital inputs
0
Output current
0.5A
Type of digital output
Other
Type of output voltage
DC
Digital inputs configurable
No
Number of HW-interfaces industrial Ethernet
0
Digital outputs configurable
Yes
Type of voltage (input voltage)
DC
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Voltage type of supply voltage
DC
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
0
With optical interface
No
Input current at signal 1
0.4mA
Supporting protocol for KNX
No
Permitted voltage at input
19.2 - 30V
Number of HW-interfaces USB
0
Supporting protocol for SUCONET
No
Number of digital outputs
16
Supporting protocol for ASI
No
Number of HW-interfaces Wireless
0
Supporting protocol for TCP/IP
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for PROFINET IO
No
Number of HW-interfaces RS-232
0
Supporting protocol for Modbus
Yes
Short-circuit protection, outputs available
Yes
Supporting protocol for EtherCAT
No
Permitted voltage at output
24 - 24V
Supporting protocol for INTERBUS
Yes
Number of interfaces PROFINET
0
Supporting protocol for CAN
Yes
Supporting protocol for DeviceNet
Yes
Supporting protocol for LON
No
Number of HW-interfaces other
0
Radio standard GPRS
No
Radio standard GSM
No
Radio standard UMTS
No
System accessory
Yes
IO link master
No
Degree of protection (IP)
IP20
Type of electric connection
Screw connection
Time delay at signal exchange
2 - 2ms
Rail mounting possible
No
Wall mounting/direct mounting
No
Fieldbus connection over separate bus coupler possible
Yes
Rack-assembly possible
Yes
Suitable for safety functions
No
Front built-in possible
No
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location class I
No
Certified for UL hazardous location group A (acetylene)
No
Explosion safety category for dust
None
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Certified for UL hazardous location group G (non-conductive dusts)
No
Height
13.9mm
Width
128.3mm
Depth
70mm
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Radio standard Bluetooth
No
Radio standard Wi-Fi 802.11
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
STBDDO3705KS
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- .. -V
Supply voltage AC 60 Hz
- .. -V
Supply voltage DC
24 .. 24V
Number of digital inputs
0
Output current
0.5A
Type of digital output
Other
Type of output voltage
DC
Digital inputs configurable
Number of HW-interfaces industrial Ethernet
0
Digital outputs configurable
Type of voltage (input voltage)
DC
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Voltage type of supply voltage
DC
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
0
With optical interface
Input current at signal 1
0.4mA
Supporting protocol for KNX
Permitted voltage at input
19.2 .. 30V
Number of HW-interfaces USB
0
Supporting protocol for SUCONET
Number of digital outputs
16
Supporting protocol for ASI
Number of HW-interfaces Wireless
0
Supporting protocol for TCP/IP
Supporting protocol for Data-Highway
Supporting protocol for PROFIBUS
Supporting protocol for PROFINET IO
Number of HW-interfaces RS-232
0
Supporting protocol for Modbus
Short-circuit protection, outputs available
Supporting protocol for EtherCAT
Permitted voltage at output
24 .. 24V
Supporting protocol for INTERBUS
Number of interfaces PROFINET
0
Supporting protocol for CAN
Supporting protocol for DeviceNet
Supporting protocol for LON
Number of HW-interfaces other
0
Radio standard GPRS
Radio standard GSM
Radio standard UMTS
System accessory
IO link master
Degree of protection (IP)
IP20
Type of electric connection
Screw connection
Time delay at signal exchange
2 .. 2ms
Rail mounting possible
Wall mounting/direct mounting
Fieldbus connection over separate bus coupler possible
Rack-assembly possible
Suitable for safety functions
Front built-in possible
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Explosion safety category for gas
None
Certified for UL hazardous location class II
Certified for UL hazardous location class III
Certified for UL hazardous location division 1
Certified for UL hazardous location class I
Certified for UL hazardous location group A (acetylene)
Explosion safety category for dust
None
Certified for UL hazardous location division 2
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Height
13.9mm
Width
128.3mm
Depth
70mm
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Radio standard Bluetooth