Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supply voltage AC 50 Hz

- - -V

Supply voltage AC 60 Hz

- - -V

Voltage type of supply voltage

DC

Supply voltage DC

24 - 24V

Number of digital outputs

6

Output current

0.5A

Type of output voltage

DC

Number of digital inputs

0

Digital outputs configurable

Yes

Input current at signal 1

0.4mA

Number of interfaces PROFINET

0

Permitted voltage at input

19.2 - 30V

Short-circuit protection, outputs available

Yes

Number of HW-interfaces USB

0

Type of digital output

Other

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

Yes

Supporting protocol for INTERBUS

Yes

Supporting protocol for ASI

No

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for KNX

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for Modbus

Yes

Number of HW-interfaces Wireless

0

Supporting protocol for DeviceNet

Yes

Type of voltage (input voltage)

DC

Supporting protocol for PROFIBUS

Yes

Permitted voltage at output

24 - 24V

Supporting protocol for Data-Highway

No

Supporting protocol for PROFINET IO

No

Digital inputs configurable

No

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces parallel

0

Supporting protocol for CAN

Yes

Number of HW-interfaces RS-422

0

Supporting protocol for LON

No

Number of HW-interfaces RS-232

0

With optical interface

No

Supporting protocol for SERCOS

No

Supporting protocol for SUCONET

No

IO link master

No

Radio standard GSM

No

System accessory

Yes

Degree of protection (IP)

IP20

Time delay at signal exchange

0.715 - 0.955ms

Type of electric connection

Screw connection

Radio standard UMTS

No

Fieldbus connection over separate bus coupler possible

Yes

Rail mounting possible

No

Wall mounting/direct mounting

No

Front built-in possible

No

Rack-assembly possible

Yes

Suitable for safety functions

No

SIL according to IEC 61508

None

Appendant operation agent (Ex ia)

No

Performance level according to EN ISO 13849-1

None

Appendant operation agent (Ex ib)

No

Explosion safety category for dust

None

Explosion safety category for gas

None

Width

128.3mm

Height

13.9mm

Depth

70mm

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for EtherNet/IP

Yes

Supporting protocol for DeviceNet Safety

No

Supporting protocol for other bus systems

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Radio standard Bluetooth

No

Radio standard Wi-Fi 802.11

No

Radio standard GPRS

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

STBDDO3600K

Main Product Image

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supply voltage AC 50 Hz

- .. -V

Supply voltage AC 60 Hz

- .. -V

Voltage type of supply voltage

DC

Supply voltage DC

24 .. 24V

Number of digital outputs

6

Output current

0.5A

Type of output voltage

DC

Number of digital inputs

0

Digital outputs configurable

Input current at signal 1

0.4mA

Number of interfaces PROFINET

0

Permitted voltage at input

19.2 .. 30V

Short-circuit protection, outputs available

Number of HW-interfaces USB

0

Type of digital output

Other

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for ASI

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for KNX

Supporting protocol for PROFINET CBA

Supporting protocol for Modbus

Number of HW-interfaces Wireless

0

Supporting protocol for DeviceNet

Type of voltage (input voltage)

DC

Supporting protocol for PROFIBUS

Permitted voltage at output

24 .. 24V

Supporting protocol for Data-Highway

Supporting protocol for PROFINET IO

Digital inputs configurable

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces parallel

0

Supporting protocol for CAN

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Number of HW-interfaces RS-232

0

With optical interface

Supporting protocol for SERCOS

Supporting protocol for SUCONET

IO link master

Radio standard GSM

System accessory

Degree of protection (IP)

IP20

Time delay at signal exchange

0.715 .. 0.955ms

Type of electric connection

Screw connection

Radio standard UMTS

Fieldbus connection over separate bus coupler possible

Rail mounting possible

Wall mounting/direct mounting

Front built-in possible

Rack-assembly possible

Suitable for safety functions

SIL according to IEC 61508

None

Appendant operation agent (Ex ia)

Performance level according to EN ISO 13849-1

None

Appendant operation agent (Ex ib)

Explosion safety category for dust

None

Explosion safety category for gas

None

Width

128.3mm

Height

13.9mm

Depth

70mm

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for other bus systems

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Radio standard Bluetooth

Radio standard Wi-Fi 802.11

Radio standard GPRS

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.