Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- - -V
Supply voltage AC 60 Hz
- - -V
Number of digital inputs
0
Voltage type of supply voltage
DC
Supply voltage DC
24 - 24V
Digital outputs configurable
Yes
Digital inputs configurable
No
Type of voltage (input voltage)
DC
Type of output voltage
DC
Number of digital outputs
6
Permitted voltage at input
19.2 - 30V
Type of digital output
Other
Permitted voltage at output
24 - 24V
Number of interfaces PROFINET
0
Input current at signal 1
0.4mA
Number of HW-interfaces RS-422
0
Short-circuit protection, outputs available
Yes
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Supporting protocol for CAN
Yes
Supporting protocol for INTERBUS
Yes
With optical interface
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for DeviceNet
Yes
Supporting protocol for TCP/IP
Yes
Supporting protocol for KNX
No
Supporting protocol for ASI
No
Supporting protocol for PROFINET IO
No
Output current
0.5A
Supporting protocol for PROFINET CBA
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for SafetyBUS p
No
Radio standard Wi-Fi 802.11
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet Safety
No
Number of HW-interfaces industrial Ethernet
0
Radio standard Bluetooth
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for AS-Interface Safety at Work
No
Radio standard GPRS
No
Supporting protocol for SERCOS
No
Supporting protocol for Modbus
Yes
Number of HW-interfaces RS-485
0
Supporting protocol for other bus systems
No
Supporting protocol for Data-Highway
No
Radio standard GSM
No
Radio standard UMTS
No
IO link master
No
Degree of protection (IP)
IP20
System accessory
Yes
Fieldbus connection over separate bus coupler possible
Yes
Type of electric connection
Screw connection
Time delay at signal exchange
0.715 - 0.955ms
Wall mounting/direct mounting
No
Suitable for safety functions
No
Rack-assembly possible
Yes
Front built-in possible
No
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Rail mounting possible
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
128.3mm
Depth
70mm
Height
13.9mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
STBDDO3600K

Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- .. -V
Supply voltage AC 60 Hz
- .. -V
Number of digital inputs
0
Voltage type of supply voltage
DC
Supply voltage DC
24 .. 24V
Digital outputs configurable
Digital inputs configurable
Type of voltage (input voltage)
DC
Type of output voltage
DC
Number of digital outputs
6
Permitted voltage at input
19.2 .. 30V
Type of digital output
Other
Permitted voltage at output
24 .. 24V
Number of interfaces PROFINET
0
Input current at signal 1
0.4mA
Number of HW-interfaces RS-422
0
Short-circuit protection, outputs available
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Supporting protocol for CAN
Supporting protocol for INTERBUS
With optical interface
Supporting protocol for PROFIBUS
Supporting protocol for DeviceNet
Supporting protocol for TCP/IP
Supporting protocol for KNX
Supporting protocol for ASI
Supporting protocol for PROFINET IO
Output current
0.5A
Supporting protocol for PROFINET CBA
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for EtherNet/IP
Supporting protocol for SafetyBUS p
Radio standard Wi-Fi 802.11
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Number of HW-interfaces industrial Ethernet
0
Radio standard Bluetooth
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for AS-Interface Safety at Work
Radio standard GPRS
Supporting protocol for SERCOS
Supporting protocol for Modbus
Number of HW-interfaces RS-485
0
Supporting protocol for other bus systems
Supporting protocol for Data-Highway
Radio standard GSM
Radio standard UMTS
IO link master
Degree of protection (IP)
IP20
System accessory
Fieldbus connection over separate bus coupler possible
Type of electric connection
Screw connection
Time delay at signal exchange
0.715 .. 0.955ms
Wall mounting/direct mounting
Suitable for safety functions
Rack-assembly possible
Front built-in possible
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
Rail mounting possible
Appendant operation agent (Ex ib)
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
128.3mm
Depth
70mm
Height
13.9mm
From same serie
We use cookies to enhance your experience.