Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- - -V
Supply voltage AC 60 Hz
- - -V
Input current at signal 1
-mA
Supply voltage DC
24 - 24V
Number of digital inputs
0
Voltage type of supply voltage
AC/DC
Digital inputs configurable
No
Number of digital outputs
2
Type of output voltage
AC/DC
Digital outputs configurable
Yes
Permitted voltage at input
19.2 - 30V
Type of voltage (input voltage)
AC/DC
Output current
2A
Number of interfaces PROFINET
0
Short-circuit protection, outputs available
Yes
Number of HW-interfaces RS-422
0
Permitted voltage at output
24 - 24V
Supporting protocol for INTERBUS
Yes
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
0
With optical interface
No
Supporting protocol for TCP/IP
Yes
Number of HW-interfaces other
0
Number of HW-interfaces Wireless
0
Supporting protocol for SUCONET
No
Supporting protocol for KNX
No
Supporting protocol for PROFINET CBA
No
Number of HW-interfaces serial TTY
0
Supporting protocol for LON
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for CAN
Yes
Type of digital output
Other
Number of HW-interfaces parallel
0
Supporting protocol for PROFINET IO
No
Supporting protocol for Modbus
Yes
Supporting protocol for SERCOS
No
Radio standard UMTS
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for Data-Highway
No
Number of HW-interfaces USB
0
Supporting protocol for ASI
No
Supporting protocol for DeviceNet
Yes
Number of HW-interfaces industrial Ethernet
0
Degree of protection (IP)
IP20
Time delay at signal exchange
0.52 - 0.72ms
Type of electric connection
Screw connection
Fieldbus connection over separate bus coupler possible
Yes
IO link master
No
System accessory
Yes
Rail mounting possible
No
Wall mounting/direct mounting
No
SIL according to IEC 61508
None
Front built-in possible
No
Rack-assembly possible
Yes
Suitable for safety functions
No
Appendant operation agent (Ex ia)
No
Explosion safety category for dust
None
Performance level according to EN ISO 13849-1
None
Width
128.3mm
Explosion safety category for gas
None
Height
13.9mm
Depth
70mm
Appendant operation agent (Ex ib)
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for other bus systems
No
Radio standard Bluetooth
No
Radio standard Wi-Fi 802.11
No
Supporting protocol for SafetyBUS p
No
Radio standard GSM
No
Supporting protocol for EtherNet/IP
Yes
Radio standard GPRS
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
STBDDO3200K

Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- .. -V
Supply voltage AC 60 Hz
- .. -V
Input current at signal 1
-mA
Supply voltage DC
24 .. 24V
Number of digital inputs
0
Voltage type of supply voltage
AC/DC
Digital inputs configurable
Number of digital outputs
2
Type of output voltage
AC/DC
Digital outputs configurable
Permitted voltage at input
19.2 .. 30V
Type of voltage (input voltage)
AC/DC
Output current
2A
Number of interfaces PROFINET
0
Short-circuit protection, outputs available
Number of HW-interfaces RS-422
0
Permitted voltage at output
24 .. 24V
Supporting protocol for INTERBUS
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
0
With optical interface
Supporting protocol for TCP/IP
Number of HW-interfaces other
0
Number of HW-interfaces Wireless
0
Supporting protocol for SUCONET
Supporting protocol for KNX
Supporting protocol for PROFINET CBA
Number of HW-interfaces serial TTY
0
Supporting protocol for LON
Supporting protocol for Foundation Fieldbus
Supporting protocol for CAN
Type of digital output
Other
Number of HW-interfaces parallel
0
Supporting protocol for PROFINET IO
Supporting protocol for Modbus
Supporting protocol for SERCOS
Radio standard UMTS
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Number of HW-interfaces USB
0
Supporting protocol for ASI
Supporting protocol for DeviceNet
Number of HW-interfaces industrial Ethernet
0
Degree of protection (IP)
IP20
Time delay at signal exchange
0.52 .. 0.72ms
Type of electric connection
Screw connection
Fieldbus connection over separate bus coupler possible
IO link master
System accessory
Rail mounting possible
Wall mounting/direct mounting
SIL according to IEC 61508
None
Front built-in possible
Rack-assembly possible
Suitable for safety functions
Appendant operation agent (Ex ia)
Explosion safety category for dust
None
Performance level according to EN ISO 13849-1
None
Width
128.3mm
Explosion safety category for gas
None
Height
13.9mm
Depth
70mm
Appendant operation agent (Ex ib)
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Supporting protocol for other bus systems
Radio standard Bluetooth
Radio standard Wi-Fi 802.11
Supporting protocol for SafetyBUS p
Radio standard GSM
Supporting protocol for EtherNet/IP
Radio standard GPRS
From same serie
We use cookies to enhance your experience.