Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP20
Width
125mm
Height
18.4mm
Depth
65.1mm
Type of electric connection
Screw connection
Explosion safety category for dust
None
Supporting protocol for SERCOS
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for EtherNet/IP
No
Performance level according to EN ISO 13849-1
None
Supporting protocol for PROFINET IO
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for CAN
No
Supporting protocol for ASI
No
SIL according to IEC 61508
None
Supporting protocol for PROFIBUS
No
Supporting protocol for PROFIsafe
No
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS
No
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Category according to EN 954-1
1
Number of HW-interfaces other
0
Suitable for safety functions
No
Explosion safety category for gas
None
Supporting protocol for Modbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for TCP/IP
No
Supporting protocol for LON
No
Supporting protocol for DeviceNet
No
Supporting protocol for KNX
No
Number of HW-interfaces parallel
0
Supporting protocol for other bus systems
No
Number of interfaces PROFINET
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
With optical interface
No
Number of digital inputs
16
Number of digital outputs
0
Voltage type of supply voltage
DC
Appendant operation agent (Ex ib)
No
Appendant operation agent (Ex ia)
No
Supply voltage DC
24 - 24V
Supply voltage AC 50 Hz
- - undefinedV
Supply voltage AC 60 Hz
- - undefinedV
Wall mounting/direct mounting
No
Radio standard GSM
No
Radio standard GPRS
No
Radio standard UMTS
No
IO link master
No
Radio standard Bluetooth
No
Radio standard Wi-Fi 802.11
No
Number of HW-interfaces Wireless
0
Front built-in possible
No
Rack-assembly possible
Yes
Rail mounting possible
No
System accessory
Yes
Type of voltage (input voltage)
DC
Type of output voltage
DC
Output current
0A
Time delay at signal exchange
2 - 2ms
Digital inputs configurable
No
Permitted voltage at input
-3 - 30V
Input current at signal 1
4.5mA
Short-circuit protection, outputs available
No
Permitted voltage at output
- - undefinedV
Digital outputs configurable
No
Type of digital output
None
Fieldbus connection over separate bus coupler possible
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
STBDDI3725
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP20
Width
125mm
Height
18.4mm
Depth
65.1mm
Type of electric connection
Screw connection
Explosion safety category for dust
None
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for SUCONET
Supporting protocol for DeviceNet Safety
Supporting protocol for EtherNet/IP
Performance level according to EN ISO 13849-1
None
Supporting protocol for PROFINET IO
Supporting protocol for SafetyBUS p
Supporting protocol for CAN
Supporting protocol for ASI
SIL according to IEC 61508
None
Supporting protocol for PROFIBUS
Supporting protocol for PROFIsafe
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Category according to EN 954-1
1
Number of HW-interfaces other
0
Suitable for safety functions
Explosion safety category for gas
None
Supporting protocol for Modbus
Supporting protocol for PROFINET CBA
Supporting protocol for TCP/IP
Supporting protocol for LON
Supporting protocol for DeviceNet
Supporting protocol for KNX
Number of HW-interfaces parallel
0
Supporting protocol for other bus systems
Number of interfaces PROFINET
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
With optical interface
Number of digital inputs
16
Number of digital outputs
0
Voltage type of supply voltage
DC
Appendant operation agent (Ex ib)
Appendant operation agent (Ex ia)
Supply voltage DC
24 .. 24V
Supply voltage AC 50 Hz
- .. undefinedV
Supply voltage AC 60 Hz
- .. undefinedV
Wall mounting/direct mounting
Radio standard GSM
Radio standard GPRS
Radio standard UMTS
IO link master
Radio standard Bluetooth
Radio standard Wi-Fi 802.11
Number of HW-interfaces Wireless
0
Front built-in possible
Rack-assembly possible
Rail mounting possible
System accessory
Type of voltage (input voltage)
DC
Type of output voltage
DC
Output current
0A
Time delay at signal exchange
2 .. 2ms
Digital inputs configurable
Permitted voltage at input
-3 .. 30V
Input current at signal 1
4.5mA
Short-circuit protection, outputs available
Permitted voltage at output
- .. undefinedV
Digital outputs configurable
Type of digital output
None
Fieldbus connection over separate bus coupler possible
From same serie
We use cookies to enhance your experience.