Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- - -V
Supply voltage AC 60 Hz
- - -V
Output current
0A
Permitted voltage at output
0 - 0V
Supply voltage DC
24 - 24V
Number of digital inputs
6
Digital inputs configurable
No
Type of digital output
None
Permitted voltage at input
-3 - 30V
Type of voltage (input voltage)
DC
Number of HW-interfaces parallel
0
Short-circuit protection, outputs available
No
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces other
0
With optical interface
No
Number of HW-interfaces RS-485
0
Number of HW-interfaces RS-232
0
Number of digital outputs
0
Input current at signal 1
2mA
Voltage type of supply voltage
DC
Type of output voltage
DC
Number of interfaces PROFINET
0
Digital outputs configurable
No
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-422
0
Supporting protocol for TCP/IP
Yes
Supporting protocol for PROFIBUS
Yes
Number of HW-interfaces Wireless
0
Supporting protocol for CAN
Yes
Supporting protocol for ASI
No
Supporting protocol for LON
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SERCOS
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
Yes
IO link master
No
Supporting protocol for Modbus
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for KNX
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFIsafe
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for INTERBUS
Yes
System accessory
Yes
Type of electric connection
Screw connection
Fieldbus connection over separate bus coupler possible
Yes
Degree of protection (IP)
IP20
Time delay at signal exchange
1.21 - 1.74ms
Rail mounting possible
No
Wall mounting/direct mounting
No
Front built-in possible
No
Rack-assembly possible
Yes
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Suitable for safety functions
No
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
125mm
Height
18.4mm
Depth
65.1mm
Radio standard Bluetooth
No
Supporting protocol for other bus systems
No
Supporting protocol for SafetyBUS p
No
Radio standard GPRS
No
Radio standard Wi-Fi 802.11
No
Radio standard GSM
No
Radio standard UMTS
No
From same serie
STBDDI3610K

Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- .. -V
Supply voltage AC 60 Hz
- .. -V
Output current
0A
Permitted voltage at output
0 .. 0V
Supply voltage DC
24 .. 24V
Number of digital inputs
6
Digital inputs configurable
Type of digital output
None
Permitted voltage at input
-3 .. 30V
Type of voltage (input voltage)
DC
Number of HW-interfaces parallel
0
Short-circuit protection, outputs available
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces other
0
With optical interface
Number of HW-interfaces RS-485
0
Number of HW-interfaces RS-232
0
Number of digital outputs
0
Input current at signal 1
2mA
Voltage type of supply voltage
DC
Type of output voltage
DC
Number of interfaces PROFINET
0
Digital outputs configurable
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-422
0
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Number of HW-interfaces Wireless
0
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for LON
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SERCOS
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
IO link master
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for KNX
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFINET IO
Supporting protocol for PROFIsafe
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS
System accessory
Type of electric connection
Screw connection
Fieldbus connection over separate bus coupler possible
Degree of protection (IP)
IP20
Time delay at signal exchange
1.21 .. 1.74ms
Rail mounting possible
Wall mounting/direct mounting
Front built-in possible
Rack-assembly possible
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Suitable for safety functions
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
125mm
Height
18.4mm
Depth
65.1mm
Radio standard Bluetooth
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Radio standard GPRS
Radio standard Wi-Fi 802.11
Radio standard GSM
Radio standard UMTS
From same serie