Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- - -V
Supply voltage AC 60 Hz
- - -V
Output current
0A
Permitted voltage at output
0 - 0V
Supply voltage DC
24 - 24V
Voltage type of supply voltage
AC/DC
Permitted voltage at input
-3 - 30V
Type of digital output
None
Number of HW-interfaces industrial Ethernet
0
Type of voltage (input voltage)
AC/DC
Input current at signal 1
2.5mA
Number of HW-interfaces RS-422
0
Type of output voltage
AC/DC
Number of HW-interfaces Wireless
0
Number of HW-interfaces serial TTY
0
Number of digital outputs
0
Number of HW-interfaces parallel
0
Number of interfaces PROFINET
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Number of HW-interfaces RS-485
0
Supporting protocol for CAN
No
With optical interface
No
Supporting protocol for TCP/IP
No
Short-circuit protection, outputs available
No
Supporting protocol for Modbus
No
Supporting protocol for KNX
No
Supporting protocol for PROFIBUS
No
Digital inputs configurable
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SUCONET
No
Supporting protocol for ASI
No
Supporting protocol for LON
No
Supporting protocol for DeviceNet
No
Number of digital inputs
4
Digital outputs configurable
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS
No
Supporting protocol for SERCOS
No
Number of HW-interfaces RS-232
0
IO link master
No
System accessory
Yes
Degree of protection (IP)
IP20
Type of electric connection
Screw-/spring clamp connection
Time delay at signal exchange
3.5 - 3.8ms
Fieldbus connection over separate bus coupler possible
Yes
Rail mounting possible
No
Wall mounting/direct mounting
No
Front built-in possible
No
Rack-assembly possible
Yes
Suitable for safety functions
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Height
18.4mm
Explosion safety category for dust
None
Depth
65.1mm
Width
125mm
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Radio standard Bluetooth
No
Supporting protocol for other bus systems
No
Radio standard Wi-Fi 802.11
No
Supporting protocol for DeviceNet Safety
No
Radio standard UMTS
No
Radio standard GSM
No
Supporting protocol for PROFIsafe
No
Radio standard GPRS
No
From same serie
STBDDI3425K

Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- .. -V
Supply voltage AC 60 Hz
- .. -V
Output current
0A
Permitted voltage at output
0 .. 0V
Supply voltage DC
24 .. 24V
Voltage type of supply voltage
AC/DC
Permitted voltage at input
-3 .. 30V
Type of digital output
None
Number of HW-interfaces industrial Ethernet
0
Type of voltage (input voltage)
AC/DC
Input current at signal 1
2.5mA
Number of HW-interfaces RS-422
0
Type of output voltage
AC/DC
Number of HW-interfaces Wireless
0
Number of HW-interfaces serial TTY
0
Number of digital outputs
0
Number of HW-interfaces parallel
0
Number of interfaces PROFINET
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Number of HW-interfaces RS-485
0
Supporting protocol for CAN
With optical interface
Supporting protocol for TCP/IP
Short-circuit protection, outputs available
Supporting protocol for Modbus
Supporting protocol for KNX
Supporting protocol for PROFIBUS
Digital inputs configurable
Supporting protocol for PROFINET IO
Supporting protocol for SUCONET
Supporting protocol for ASI
Supporting protocol for LON
Supporting protocol for DeviceNet
Number of digital inputs
4
Digital outputs configurable
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Supporting protocol for SERCOS
Number of HW-interfaces RS-232
0
IO link master
System accessory
Degree of protection (IP)
IP20
Type of electric connection
Screw-/spring clamp connection
Time delay at signal exchange
3.5 .. 3.8ms
Fieldbus connection over separate bus coupler possible
Rail mounting possible
Wall mounting/direct mounting
Front built-in possible
Rack-assembly possible
Suitable for safety functions
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Explosion safety category for gas
None
Height
18.4mm
Explosion safety category for dust
None
Depth
65.1mm
Width
125mm
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Radio standard Bluetooth
Supporting protocol for other bus systems
Radio standard Wi-Fi 802.11
Supporting protocol for DeviceNet Safety
Radio standard UMTS
Radio standard GSM
Supporting protocol for PROFIsafe
Radio standard GPRS
From same serie
We use cookies to enhance your experience.