Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage DC
- - -V
Output current
0A
Permitted voltage at output
0 - 0V
Supply voltage AC 60 Hz
115 - 115V
Supply voltage AC 50 Hz
115 - 115V
Voltage type of supply voltage
AC/DC
Number of digital outputs
0
Number of digital inputs
2
Digital inputs configurable
No
Digital outputs configurable
No
Short-circuit protection, outputs available
No
Number of HW-interfaces industrial Ethernet
0
Permitted voltage at input
-3 - 30V
Input current at signal 1
2.5mA
Type of voltage (input voltage)
AC/DC
Number of HW-interfaces RS-232
0
Type of output voltage
AC/DC
Type of digital output
None
Number of HW-interfaces RS-422
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Number of HW-interfaces Wireless
0
With optical interface
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for KNX
No
Supporting protocol for INTERBUS
Yes
Number of HW-interfaces parallel
0
Supporting protocol for CAN
Yes
Supporting protocol for ASI
No
Supporting protocol for TCP/IP
Yes
Supporting protocol for DeviceNet
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
Yes
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SUCONET
No
Radio standard UMTS
No
IO link master
No
System accessory
Yes
Degree of protection (IP)
IP20
Type of electric connection
Screw connection
Time delay at signal exchange
0.925 - 1.35ms
Rail mounting possible
No
Fieldbus connection over separate bus coupler possible
Yes
Wall mounting/direct mounting
No
Rack-assembly possible
No
Front built-in possible
No
Suitable for safety functions
No
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
125mm
Depth
65.1mm
Height
18.4mm
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Radio standard Bluetooth
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Radio standard GPRS
No
Radio standard Wi-Fi 802.11
No
Radio standard GSM
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
STBDAI5230K

Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage DC
- .. -V
Output current
0A
Permitted voltage at output
0 .. 0V
Supply voltage AC 60 Hz
115 .. 115V
Supply voltage AC 50 Hz
115 .. 115V
Voltage type of supply voltage
AC/DC
Number of digital outputs
0
Number of digital inputs
2
Digital inputs configurable
Digital outputs configurable
Short-circuit protection, outputs available
Number of HW-interfaces industrial Ethernet
0
Permitted voltage at input
-3 .. 30V
Input current at signal 1
2.5mA
Type of voltage (input voltage)
AC/DC
Number of HW-interfaces RS-232
0
Type of output voltage
AC/DC
Type of digital output
None
Number of HW-interfaces RS-422
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Number of HW-interfaces Wireless
0
With optical interface
Supporting protocol for PROFIBUS
Supporting protocol for KNX
Supporting protocol for INTERBUS
Number of HW-interfaces parallel
0
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for TCP/IP
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for SUCONET
Radio standard UMTS
IO link master
System accessory
Degree of protection (IP)
IP20
Type of electric connection
Screw connection
Time delay at signal exchange
0.925 .. 1.35ms
Rail mounting possible
Fieldbus connection over separate bus coupler possible
Wall mounting/direct mounting
Rack-assembly possible
Front built-in possible
Suitable for safety functions
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
125mm
Depth
65.1mm
Height
18.4mm
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Radio standard Bluetooth
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Radio standard GPRS
Radio standard Wi-Fi 802.11
Radio standard GSM
From same serie
We use cookies to enhance your experience.