Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - analogue I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- - -V
Supply voltage AC 60 Hz
- - -V
Voltage type of supply voltage
AC/DC
Supply voltage DC
10 - 10V
Input, current
Yes
Resolution of the analogue inputs
15Bit
Resolution of the analogue outputs
15Bit
Analogue inputs configurable
Yes
Input, thermocouple
No
Number of analogue inputs
8
Number of analogue outputs
0
Output signal configurable
No
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-485
0
Supporting protocol for EtherCAT
No
Number of HW-interfaces Wireless
0
Number of HW-interfaces other
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of interfaces PROFINET
0
Output, voltage
No
Number of HW-interfaces RS-232
0
Supporting protocol for INTERBUS
No
Input, voltage
No
Input signal, configurable
Yes
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for SUCONET
No
Input, resistance thermometer
No
Input, resistor
No
Supporting protocol for ASI
No
Number of HW-interfaces parallel
0
Supporting protocol for Modbus
No
Number of HW-interfaces RS-422
0
Supporting protocol for PROFINET CBA
No
Supporting protocol for DeviceNet
No
Output, current
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for SERCOS
No
Analogue outputs configurable
No
Supporting protocol for TCP/IP
No
Supporting protocol for KNX
No
Radio standard Bluetooth
No
Supporting protocol for LON
No
Radio standard Wi-Fi 802.11
No
Radio standard GSM
No
Radio standard GPRS
No
Radio standard UMTS
No
IO link master
No
Degree of protection (IP)
IP20
System accessory
Yes
Type of electric connection
Screw connection
Fieldbus connection over separate bus coupler possible
Yes
Rail mounting possible
Yes
Wall mounting/direct mounting
No
Front built-in possible
No
Rack-assembly possible
Yes
Suitable for safety functions
No
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ib)
No
Appendant operation agent (Ex ia)
No
Explosion safety category for gas
ATEX gas-ex-protection, Cat. 3G
Explosion safety category for dust
Other
SIL according to IEC 61508
None
Certified for UL hazardous location class I
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Certified for UL hazardous location group G (non-conductive dusts)
No
Width
128.3mm
Height
18.4mm
Depth
70mm
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for SafetyBUS p
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
STBAVI1400K
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - analogue I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- .. -V
Supply voltage AC 60 Hz
- .. -V
Voltage type of supply voltage
AC/DC
Supply voltage DC
10 .. 10V
Input, current
Resolution of the analogue inputs
15Bit
Resolution of the analogue outputs
15Bit
Analogue inputs configurable
Input, thermocouple
Number of analogue inputs
8
Number of analogue outputs
0
Output signal configurable
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-485
0
Supporting protocol for EtherCAT
Number of HW-interfaces Wireless
0
Number of HW-interfaces other
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of interfaces PROFINET
0
Output, voltage
Number of HW-interfaces RS-232
0
Supporting protocol for INTERBUS
Input, voltage
Input signal, configurable
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for SUCONET
Input, resistance thermometer
Input, resistor
Supporting protocol for ASI
Number of HW-interfaces parallel
0
Supporting protocol for Modbus
Number of HW-interfaces RS-422
0
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet
Output, current
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Supporting protocol for Data-Highway
Supporting protocol for SERCOS
Analogue outputs configurable
Supporting protocol for TCP/IP
Supporting protocol for KNX
Radio standard Bluetooth
Supporting protocol for LON
Radio standard Wi-Fi 802.11
Radio standard GSM
Radio standard GPRS
Radio standard UMTS
IO link master
Degree of protection (IP)
IP20
System accessory
Type of electric connection
Screw connection
Fieldbus connection over separate bus coupler possible
Rail mounting possible
Wall mounting/direct mounting
Front built-in possible
Rack-assembly possible
Suitable for safety functions
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ib)
Appendant operation agent (Ex ia)
Explosion safety category for gas
ATEX gas-ex-protection, Cat. 3G
Explosion safety category for dust
Other
SIL according to IEC 61508
None
Certified for UL hazardous location class I
Certified for UL hazardous location class II
Certified for UL hazardous location class III
Certified for UL hazardous location division 1
Certified for UL hazardous location division 2
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Width
128.3mm
Height
18.4mm
Depth
70mm
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
From same serie
We use cookies to enhance your experience.