SR3B261FU
Code: 1714253
Code: 1714253
Supply voltage DC
- - -V
Number of digital inputs
16
Number of analogue outputs
0
Supply voltage AC 50 Hz
100 - 240V
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of analogue inputs
0
Supporting protocol for TCP/IP
No
Number of HW-interfaces Wireless
0
With optical interface
No
Supporting protocol for CAN
No
Supporting protocol for Modbus
No
Supply voltage AC 60 Hz
100 - 240V
Number of digital outputs
10
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for SUCONET
No
Supporting protocol for KNX
No
With relay output
Yes
Supporting protocol for DeviceNet
No
Supporting protocol for PROFIBUS
No
Supporting protocol for LON
No
Voltage type of supply voltage
AC
Switching current
8A
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS
No
Supporting protocol for SERCOS
No
Number of HW-interfaces RS-485
0
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for EtherCAT
No
Supporting protocol for PROFINET IO
No
Supporting protocol for ASI
No
Power consumption
12W
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for DeviceNet Safety
No
Number of interfaces PROFINET
0
Number of HW-interfaces other
1
Redundancy
No
With display
Yes
Degree of protection (IP)
IP20
Basic device
Yes
Expandable
Yes
Expansion device
No
With time switch clock
Yes
Rail mounting possible
Yes
Wall mounting/direct mounting
Yes
Front built-in possible
Yes
Suitable for safety functions
No
SIL according to IEC 61508
None
Rack-assembly possible
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Certified for UL hazardous location class I
No
Appendant operation agent (Ex ia)
No
Explosion safety category for dust
None
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group G (non-conductive dusts)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 1
No
Width
124.6mm
Depth
59.5mm
Height
90mm
Radio standard UMTS
No
Radio standard GPRS
No
Supporting protocol for SafetyBUS p
No
Radio standard Bluetooth
No
Supporting protocol for other bus systems
No
Radio standard Wi-Fi 802.11
No
Radio standard GSM
No
Supporting protocol for PROFIsafe
No
IO link master
No
Category according to EN 954-1
1
Zagreb:
0 pcs
Zadar:
0 pcs
SR3B261FU
Supply voltage DC
- .. -V
Number of digital inputs
16
Number of analogue outputs
0
Supply voltage AC 50 Hz
100 .. 240V
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of analogue inputs
0
Supporting protocol for TCP/IP
Number of HW-interfaces Wireless
0
With optical interface
Supporting protocol for CAN
Supporting protocol for Modbus
Supply voltage AC 60 Hz
100 .. 240V
Number of digital outputs
10
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for SUCONET
Supporting protocol for KNX
With relay output
Supporting protocol for DeviceNet
Supporting protocol for PROFIBUS
Supporting protocol for LON
Voltage type of supply voltage
AC
Switching current
8A
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS
Supporting protocol for SERCOS
Number of HW-interfaces RS-485
0
Supporting protocol for INTERBUS-Safety
Supporting protocol for EtherCAT
Supporting protocol for PROFINET IO
Supporting protocol for ASI
Power consumption
12W
Supporting protocol for Data-Highway
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Number of interfaces PROFINET
0
Number of HW-interfaces other
1
Redundancy
With display
Degree of protection (IP)
IP20
Basic device
Expandable
Expansion device
With time switch clock
Rail mounting possible
Wall mounting/direct mounting
Front built-in possible
Suitable for safety functions
SIL according to IEC 61508
None
Rack-assembly possible
Appendant operation agent (Ex ib)
Explosion safety category for gas
None
Certified for UL hazardous location class I
Appendant operation agent (Ex ia)
Explosion safety category for dust
None
Certified for UL hazardous location class II
Certified for UL hazardous location class III
Certified for UL hazardous location division 2
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group G (non-conductive dusts)
Certified for UL hazardous location group F (carbonaceous dusts)
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 1
Width
124.6mm
Depth
59.5mm
Height
90mm
Radio standard UMTS
Radio standard GPRS
Supporting protocol for SafetyBUS p
Radio standard Bluetooth
Supporting protocol for other bus systems
Radio standard Wi-Fi 802.11
Radio standard GSM
Supporting protocol for PROFIsafe
IO link master
Category according to EN 954-1
1
We use cookies to enhance your experience.