Details
- Programmable logic controllers PLC
- Logic module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- - -V
Supply voltage AC 60 Hz
- - -V
Supply voltage DC
24 - 24V
Switching current
8A
Number of analogue outputs
0
Number of digital outputs
4
Number of analogue inputs
0
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
With relay output
Yes
Number of digital inputs
6
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces other
1
Voltage type of supply voltage
AC/DC
Number of HW-interfaces RS-422
0
Number of HW-interfaces USB
0
Supporting protocol for TCP/IP
No
With optical interface
No
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-232
1
Supporting protocol for KNX
No
Number of HW-interfaces Wireless
0
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Supporting protocol for SUCONET
No
Supporting protocol for CAN
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET IO
No
Supporting protocol for DeviceNet
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for Modbus
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Basic device
Yes
Expandable
No
Expansion device
No
With time switch clock
No
Rail mounting possible
Yes
Wall mounting/direct mounting
Yes
Rack-assembly possible
No
Performance level according to EN ISO 13849-1
None
Suitable for safety functions
No
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Height
90mm
Width
71.2mm
Explosion safety category for dust
None
Depth
59.5mm
Front built-in possible
Yes
Radio standard GSM
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for DeviceNet Safety
No
Radio standard Wi-Fi 802.11
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for other bus systems
No
Degree of protection (IP)
IP20
IO link master
No
Supporting protocol for PROFIsafe
No
Radio standard UMTS
No
With display
No
Radio standard Bluetooth
No
Radio standard GPRS
No
Redundancy
No
From same serie
SR2D101BD

Details
- Programmable logic controllers PLC
- Logic module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- .. -V
Supply voltage AC 60 Hz
- .. -V
Supply voltage DC
24 .. 24V
Switching current
8A
Number of analogue outputs
0
Number of digital outputs
4
Number of analogue inputs
0
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
With relay output
Number of digital inputs
6
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces other
1
Voltage type of supply voltage
AC/DC
Number of HW-interfaces RS-422
0
Number of HW-interfaces USB
0
Supporting protocol for TCP/IP
With optical interface
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-232
1
Supporting protocol for KNX
Number of HW-interfaces Wireless
0
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Supporting protocol for SUCONET
Supporting protocol for CAN
Supporting protocol for SERCOS
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet
Supporting protocol for Foundation Fieldbus
Supporting protocol for Modbus
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Basic device
Expandable
Expansion device
With time switch clock
Rail mounting possible
Wall mounting/direct mounting
Rack-assembly possible
Performance level according to EN ISO 13849-1
None
Suitable for safety functions
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Explosion safety category for gas
None
Height
90mm
Width
71.2mm
Explosion safety category for dust
None
Depth
59.5mm
Front built-in possible
Radio standard GSM
Supporting protocol for SafetyBUS p
Supporting protocol for DeviceNet Safety
Radio standard Wi-Fi 802.11
Supporting protocol for INTERBUS-Safety
Supporting protocol for other bus systems
Degree of protection (IP)
IP20
IO link master
Supporting protocol for PROFIsafe
Radio standard UMTS
With display
Radio standard Bluetooth
Radio standard GPRS
Redundancy
From same serie