Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP30
Number of poles
4
Type of control element
Toggle
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
100A
Overload release current setting
- - -A
Motor drive integrated
No
Rated voltage
750 - 750V
Type of electrical connection of main circuit
Screw connection
Motor drive optional
Yes
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
- - -A
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
Adjustment range short-term delayed short-circuit release
- - -A
Position of connection for main current circuit
Front side
DIN rail (top hat rail) mounting optional
Yes
Complete device with protection unit
No
Integrated earth fault protection
No
With under voltage release
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LV438008
![Main Product Image](https://assets.aleta.hr/300x300/531c0ee9-b503-4120-abab-c99326c66aa1_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP30
Number of poles
4
Type of control element
Toggle
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
100A
Overload release current setting
- .. -A
Motor drive integrated
Rated voltage
750 .. 750V
Type of electrical connection of main circuit
Screw connection
Motor drive optional
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
- .. -A
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
Adjustment range short-term delayed short-circuit release
- .. -A
Position of connection for main current circuit
Front side
DIN rail (top hat rail) mounting optional
Complete device with protection unit
Integrated earth fault protection
With under voltage release