Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - analogue/digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- - -V
Supply voltage AC 60 Hz
- - -V
Resolution of the analogue inputs
-Bit
Resolution of the analogue outputs
-Bit
Number of analogue inputs
1
Number of digital inputs
6
Analogue inputs configurable
Yes
Digital inputs configurable
Yes
Number of analogue outputs
0
Digital outputs configurable
Yes
Voltage type of supply voltage
DC
Number of digital outputs
3
Permitted voltage at input
19.8 - 25.2V
Input current at signal 1
6.1mA
Supply voltage DC
19.2 - 26.4V
Type of voltage (input voltage)
DC
Analogue outputs configurable
No
Type of digital output
Other
Output voltage at digital output
250 - 250V
Analogue input, voltage
No
Analogue input, resistor
No
Analogue input signal configurable
Yes
Analogue output, current
No
Analogue output, voltage
No
Number of interfaces PROFINET
0
Analogue input, thermocouple
Yes
Type of output voltage
AC
Number of HW-interfaces industrial Ethernet
0
Output current at digital output
5A
Analogue output signal configurable
No
Short-circuit protection, digital outputs available
Yes
Analogue input, resistor temperature
Yes
Supporting protocol for PROFINET CBA
No
Analogue input, current
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for other bus systems
No
Radio standard Bluetooth
No
Radio standard Wi-Fi 802.11
No
Radio standard GPRS
No
Radio standard UMTS
No
Radio standard GSM
No
IO link master
Yes
System accessory
No
Type of electric connection
Screw connection
Degree of protection (IP)
IP2X
Time delay at signal exchange
0 - 20ms
Rail mounting possible
Yes
Fieldbus connection over separate bus coupler possible
No
Wall mounting/direct mounting
No
Front built-in possible
No
Rack-assembly possible
No
SIL according to IEC 61508
None
Suitable for safety functions
No
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Height
116mm
Width
71.7mm
Depth
70.6mm
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces other
2
Number of HW-interfaces Wireless
0
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
With optical interface
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for KNX
No
Supporting protocol for ASI
No
Supporting protocol for INTERBUS
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
No
Supporting protocol for PROFINET IO
No
Supporting protocol for LON
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LV434063

Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - analogue/digital I/O module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
- .. -V
Supply voltage AC 60 Hz
- .. -V
Resolution of the analogue inputs
-Bit
Resolution of the analogue outputs
-Bit
Number of analogue inputs
1
Number of digital inputs
6
Analogue inputs configurable
Digital inputs configurable
Number of analogue outputs
0
Digital outputs configurable
Voltage type of supply voltage
DC
Number of digital outputs
3
Permitted voltage at input
19.8 .. 25.2V
Input current at signal 1
6.1mA
Supply voltage DC
19.2 .. 26.4V
Type of voltage (input voltage)
DC
Analogue outputs configurable
Type of digital output
Other
Output voltage at digital output
250 .. 250V
Analogue input, voltage
Analogue input, resistor
Analogue input signal configurable
Analogue output, current
Analogue output, voltage
Number of interfaces PROFINET
0
Analogue input, thermocouple
Type of output voltage
AC
Number of HW-interfaces industrial Ethernet
0
Output current at digital output
5A
Analogue output signal configurable
Short-circuit protection, digital outputs available
Analogue input, resistor temperature
Supporting protocol for PROFINET CBA
Analogue input, current
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for INTERBUS-Safety
Supporting protocol for other bus systems
Radio standard Bluetooth
Radio standard Wi-Fi 802.11
Radio standard GPRS
Radio standard UMTS
Radio standard GSM
IO link master
System accessory
Type of electric connection
Screw connection
Degree of protection (IP)
IP2X
Time delay at signal exchange
0 .. 20ms
Rail mounting possible
Fieldbus connection over separate bus coupler possible
Wall mounting/direct mounting
Front built-in possible
Rack-assembly possible
SIL according to IEC 61508
None
Suitable for safety functions
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Height
116mm
Width
71.7mm
Depth
70.6mm
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces other
2
Number of HW-interfaces Wireless
0
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
With optical interface
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for KNX
Supporting protocol for ASI
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for PROFINET IO
Supporting protocol for LON
From same serie
We use cookies to enhance your experience.