![Main Product Image](https://assets.aleta.hr/415x415/25b6a0bb-0aaa-4c29-8eeb-cf62bf753fba.webp)
![Main Product Image](https://assets.aleta.hr/415x415/25b6a0bb-0aaa-4c29-8eeb-cf62bf753fba.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation prot.
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP30
Number of poles
4
Type of control element
Rocker lever
Rated permanent current Iu
100A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
40 - 100A
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Screw connection
Rated voltage
690 - 690V
Motor drive optional
Yes
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
0
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
150 - 1500A
With switched-off indicator
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
25kA
Adjustment range short-term delayed short-circuit release
54 - 1000A
Position of connection for main current circuit
Front connection
DIN rail (top hat rail) mounting optional
No
Complete device with protection unit
Yes
With under voltage release
No
Integrated earth fault protection
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LV429875
![Main Product Image](https://assets.aleta.hr/300x300/941207c7-cb0b-40ed-b1e5-be3d8961f00b_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation prot.
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP30
Number of poles
4
Type of control element
Rocker lever
Rated permanent current Iu
100A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
40 .. 100A
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Screw connection
Rated voltage
690 .. 690V
Motor drive optional
Motor drive integrated
Number of auxiliary contacts as change-over contact
0
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
150 .. 1500A
With switched-off indicator
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
25kA
Adjustment range short-term delayed short-circuit release
54 .. 1000A
Position of connection for main current circuit
Front connection
DIN rail (top hat rail) mounting optional
Complete device with protection unit
With under voltage release
Integrated earth fault protection
From same serie