Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Rated operation power at AC-3, 230 V, 3-phase
-kW
With short-circuit release
Yes
Voltage type for actuating
DC
Rated power, 460 V, 60 Hz, 3-phase
5.5kW
Type of motor starter
Other
Rated power, 575 V, 60 Hz, 3-phase
5.5kW
Rated operation current Ie
3A
Rated conditional short-circuit current, type 1, 600 Y/347 V
12A
Rated conditional short-circuit current, type 2, 230 V
3A
Rated conditional short-circuit current, type 2, 400 V
12A
Ambient temperature, upper operating limit
70°C
Temperature compensated overload protection
Yes
Rail mounting possible
Yes
Number of auxiliary contacts as normally closed contact
0
With fuse
No
Type of electrical connection of main circuit
Screw connection
Rated control supply voltage Us at DC
24 - 24V
With transformer
No
Number of indicator lights
0
Suitable for emergency stop
No
Rated conditional short-circuit current, type 1, 480 Y/277 V
3A
Coordination class according to IEC 60947-4-3
Class 2
External reset possible
No
Supporting protocol for CAN
No
Number of auxiliary contacts as normally open contact
0
Number of command positions
0
Supporting protocol for INTERBUS
No
Rated operation current at AC-3, 400 V
12A
Overload release current setting
3 - 12A
Rated operation power at AC-3, 400 V
5.5kW
Supporting protocol for TCP/IP
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for PROFIBUS
No
Degree of protection (IP)
IP40
Release class
CLASS 10
Supporting protocol for ASI
No
Supporting protocol for Modbus
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for AS-Interface Safety at Work
No
Width
45mm
Supporting protocol for SafetyBUS p
No
Supporting protocol for EtherNet/IP
No
Depth
60mm
Height
66mm
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for other bus systems
No
Supporting protocol for DeviceNet
No
From same serie
LUCM12BL

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated operation power at AC-3, 230 V, 3-phase
-kW
With short-circuit release
Voltage type for actuating
DC
Rated power, 460 V, 60 Hz, 3-phase
5.5kW
Type of motor starter
Other
Rated power, 575 V, 60 Hz, 3-phase
5.5kW
Rated operation current Ie
3A
Rated conditional short-circuit current, type 1, 600 Y/347 V
12A
Rated conditional short-circuit current, type 2, 230 V
3A
Rated conditional short-circuit current, type 2, 400 V
12A
Ambient temperature, upper operating limit
70°C
Temperature compensated overload protection
Rail mounting possible
Number of auxiliary contacts as normally closed contact
0
With fuse
Type of electrical connection of main circuit
Screw connection
Rated control supply voltage Us at DC
24 .. 24V
With transformer
Number of indicator lights
0
Suitable for emergency stop
Rated conditional short-circuit current, type 1, 480 Y/277 V
3A
Coordination class according to IEC 60947-4-3
Class 2
External reset possible
Supporting protocol for CAN
Number of auxiliary contacts as normally open contact
0
Number of command positions
0
Supporting protocol for INTERBUS
Rated operation current at AC-3, 400 V
12A
Overload release current setting
3 .. 12A
Rated operation power at AC-3, 400 V
5.5kW
Supporting protocol for TCP/IP
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for PROFIBUS
Degree of protection (IP)
IP40
Release class
CLASS 10
Supporting protocol for ASI
Supporting protocol for Modbus
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for AS-Interface Safety at Work
Width
45mm
Supporting protocol for SafetyBUS p
Supporting protocol for EtherNet/IP
Depth
60mm
Height
66mm
Supporting protocol for INTERBUS-Safety
Supporting protocol for other bus systems
Supporting protocol for DeviceNet
From same serie
We use cookies to enhance your experience.