Technical specifications

Rated control supply voltage Us at AC 50HZ

- - -V

Rated control supply voltage Us at AC 60HZ

- - -V

Rated operation power at AC-3, 230 V, 3-phase

-kW

With short-circuit release

Yes

Voltage type for actuating

DC

Rated power, 460 V, 60 Hz, 3-phase

5.5kW

Type of motor starter

Other

Rated power, 575 V, 60 Hz, 3-phase

5.5kW

Rated operation current Ie

3A

Rated conditional short-circuit current, type 1, 600 Y/347 V

12A

Rated conditional short-circuit current, type 2, 230 V

3A

Rated conditional short-circuit current, type 2, 400 V

12A

Ambient temperature, upper operating limit

70°C

Temperature compensated overload protection

Yes

Rail mounting possible

Yes

Number of auxiliary contacts as normally closed contact

0

With fuse

No

Type of electrical connection of main circuit

Screw connection

Rated control supply voltage Us at DC

24 - 24V

With transformer

No

Number of indicator lights

0

Suitable for emergency stop

No

Rated conditional short-circuit current, type 1, 480 Y/277 V

3A

Coordination class according to IEC 60947-4-3

Class 2

External reset possible

No

Supporting protocol for CAN

No

Number of auxiliary contacts as normally open contact

0

Number of command positions

0

Supporting protocol for INTERBUS

No

Rated operation current at AC-3, 400 V

12A

Overload release current setting

3 - 12A

Rated operation power at AC-3, 400 V

5.5kW

Supporting protocol for TCP/IP

No

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for PROFIBUS

No

Degree of protection (IP)

IP40

Release class

CLASS 10

Supporting protocol for ASI

No

Supporting protocol for Modbus

No

Supporting protocol for SUCONET

No

Supporting protocol for LON

No

Supporting protocol for SERCOS

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for PROFINET IO

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for Data-Highway

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for AS-Interface Safety at Work

No

Width

45mm

Supporting protocol for SafetyBUS p

No

Supporting protocol for EtherNet/IP

No

Depth

60mm

Height

66mm

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for other bus systems

No

Supporting protocol for DeviceNet

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

LUCM12BL

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated control supply voltage Us at AC 60HZ

- .. -V

Rated operation power at AC-3, 230 V, 3-phase

-kW

With short-circuit release

Voltage type for actuating

DC

Rated power, 460 V, 60 Hz, 3-phase

5.5kW

Type of motor starter

Other

Rated power, 575 V, 60 Hz, 3-phase

5.5kW

Rated operation current Ie

3A

Rated conditional short-circuit current, type 1, 600 Y/347 V

12A

Rated conditional short-circuit current, type 2, 230 V

3A

Rated conditional short-circuit current, type 2, 400 V

12A

Ambient temperature, upper operating limit

70°C

Temperature compensated overload protection

Rail mounting possible

Number of auxiliary contacts as normally closed contact

0

With fuse

Type of electrical connection of main circuit

Screw connection

Rated control supply voltage Us at DC

24 .. 24V

With transformer

Number of indicator lights

0

Suitable for emergency stop

Rated conditional short-circuit current, type 1, 480 Y/277 V

3A

Coordination class according to IEC 60947-4-3

Class 2

External reset possible

Supporting protocol for CAN

Number of auxiliary contacts as normally open contact

0

Number of command positions

0

Supporting protocol for INTERBUS

Rated operation current at AC-3, 400 V

12A

Overload release current setting

3 .. 12A

Rated operation power at AC-3, 400 V

5.5kW

Supporting protocol for TCP/IP

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for PROFIBUS

Degree of protection (IP)

IP40

Release class

CLASS 10

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for AS-Interface Safety at Work

Width

45mm

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

Depth

60mm

Height

66mm

Supporting protocol for INTERBUS-Safety