Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Rated operation power at AC-3, 230 V, 3-phase
-kW
Rated control supply voltage Us at DC
24 - 24V
Rated operation power at AC-3, 400 V
5.5kW
Type of motor starter
Other
Overload release current setting
1.25 - 5A
Rated power, 575 V, 60 Hz, 3-phase
3kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
1.25A
Ambient temperature, upper operating limit
70°C
Number of auxiliary contacts as normally open contact
0
Rated conditional short-circuit current, type 2, 400 V
5A
Number of auxiliary contacts as normally closed contact
0
Number of indicator lights
0
Rail mounting possible
Yes
Voltage type for actuating
DC
Rated conditional short-circuit current, type 2, 230 V
1.25A
Rated conditional short-circuit current, type 1, 600 Y/347 V
5A
Rated operation current Ie
1.25A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Degree of protection (IP)
IP40
Release class
CLASS 10
With transformer
No
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for ASI
No
Suitable for emergency stop
No
With fuse
No
External reset possible
No
With short-circuit release
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Number of command positions
0
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFIBUS
No
Supporting protocol for PROFINET IO
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Type of electrical connection of main circuit
Screw connection
Rated power, 460 V, 60 Hz, 3-phase
2.2kW
Supporting protocol for SafetyBUS p
No
Supporting protocol for LON
No
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Rated operation current at AC-3, 400 V
5A
Temperature compensated overload protection
Yes
Supporting protocol for CAN
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for TCP/IP
No
Supporting protocol for SUCONET
No
Supporting protocol for other bus systems
No
Width
45mm
Height
66mm
Depth
60mm
Supporting protocol for DeviceNet
No
From same serie
LUCM05BL

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated operation power at AC-3, 230 V, 3-phase
-kW
Rated control supply voltage Us at DC
24 .. 24V
Rated operation power at AC-3, 400 V
5.5kW
Type of motor starter
Other
Overload release current setting
1.25 .. 5A
Rated power, 575 V, 60 Hz, 3-phase
3kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
1.25A
Ambient temperature, upper operating limit
70°C
Number of auxiliary contacts as normally open contact
0
Rated conditional short-circuit current, type 2, 400 V
5A
Number of auxiliary contacts as normally closed contact
0
Number of indicator lights
0
Rail mounting possible
Voltage type for actuating
DC
Rated conditional short-circuit current, type 2, 230 V
1.25A
Rated conditional short-circuit current, type 1, 600 Y/347 V
5A
Rated operation current Ie
1.25A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Degree of protection (IP)
IP40
Release class
CLASS 10
With transformer
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for ASI
Suitable for emergency stop
With fuse
External reset possible
With short-circuit release
Supporting protocol for INTERBUS
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Number of command positions
0
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFIBUS
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Type of electrical connection of main circuit
Screw connection
Rated power, 460 V, 60 Hz, 3-phase
2.2kW
Supporting protocol for SafetyBUS p
Supporting protocol for LON
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Rated operation current at AC-3, 400 V
5A
Temperature compensated overload protection
Supporting protocol for CAN
Supporting protocol for INTERBUS-Safety
Supporting protocol for TCP/IP
Supporting protocol for SUCONET
Supporting protocol for other bus systems
Width
45mm
Height
66mm
Depth
60mm
Supporting protocol for DeviceNet
From same serie