Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated operation power at AC-3, 230 V, 3-phase
-kW
Rated power, 460 V, 60 Hz, 3-phase
-kW
Type of motor starter
Other
Rated control supply voltage Us at DC
110 - 220V
Voltage type for actuating
AC/DC
Rated control supply voltage Us at AC 50HZ
110 - 240V
Rated control supply voltage Us at AC 60HZ
110 - 240V
Rated conditional short-circuit current, type 2, 230 V
3A
Rated operation power at AC-3, 400 V
2.2kW
With short-circuit release
Yes
Ambient temperature, upper operating limit
70°C
Rated operation current at AC-3, 400 V
12A
Rated operation current Ie
3A
Overload release current setting
3 - 12A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Temperature compensated overload protection
Yes
Type of electrical connection of main circuit
Screw connection
Rated conditional short-circuit current, type 2, 400 V
12A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Release class
CLASS 10
Rated conditional short-circuit current, type 1, 480 Y/277 V
3A
Number of indicator lights
0
Rated conditional short-circuit current, type 1, 600 Y/347 V
12A
Number of command positions
0
Rail mounting possible
Yes
Suitable for emergency stop
No
Supporting protocol for TCP/IP
No
With fuse
No
Supporting protocol for CAN
No
Supporting protocol for LON
No
With transformer
No
Supporting protocol for ASI
No
Degree of protection (IP)
IP40
Supporting protocol for INTERBUS
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
External reset possible
No
Supporting protocol for Modbus
No
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for Data-Highway
No
Supporting protocol for PROFIBUS
No
Supporting protocol for PROFINET IO
No
Supporting protocol for other bus systems
No
Width
45mm
Height
66mm
Depth
60mm
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LUCC12FU

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated operation power at AC-3, 230 V, 3-phase
-kW
Rated power, 460 V, 60 Hz, 3-phase
-kW
Type of motor starter
Other
Rated control supply voltage Us at DC
110 .. 220V
Voltage type for actuating
AC/DC
Rated control supply voltage Us at AC 50HZ
110 .. 240V
Rated control supply voltage Us at AC 60HZ
110 .. 240V
Rated conditional short-circuit current, type 2, 230 V
3A
Rated operation power at AC-3, 400 V
2.2kW
With short-circuit release
Ambient temperature, upper operating limit
70°C
Rated operation current at AC-3, 400 V
12A
Rated operation current Ie
3A
Overload release current setting
3 .. 12A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Temperature compensated overload protection
Type of electrical connection of main circuit
Screw connection
Rated conditional short-circuit current, type 2, 400 V
12A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Release class
CLASS 10
Rated conditional short-circuit current, type 1, 480 Y/277 V
3A
Number of indicator lights
0
Rated conditional short-circuit current, type 1, 600 Y/347 V
12A
Number of command positions
0
Rail mounting possible
Suitable for emergency stop
Supporting protocol for TCP/IP
With fuse
Supporting protocol for CAN
Supporting protocol for LON
With transformer
Supporting protocol for ASI
Degree of protection (IP)
IP40
Supporting protocol for INTERBUS
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
External reset possible
Supporting protocol for Modbus
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for Data-Highway
Supporting protocol for PROFIBUS
Supporting protocol for PROFINET IO
Supporting protocol for other bus systems
Width
45mm
Height
66mm
Depth
60mm
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet Safety
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
From same serie
We use cookies to enhance your experience.