Aleta.hr

Details

  • Low-voltage industrial components
  • Trip block for power circuit-breaker
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Type of motor protection

Thermal/magnetic release

Short-circuit release function

Undelayed

Rated permanent current Iu

32A

External power supply required

Yes

Voltage type (operating voltage)

AC

Overload release current setting

8 - 32A

Width

45mm

With ground fault protection function

Yes

Operating voltage at AC 60 Hz

690 - 690V

Depth

60mm

Height

66mm

Operating voltage at AC 50 Hz

690 - 690V

Voltage type of supply voltage

DC

Type of motor starter

Other

With short-circuit release

Yes

Rated operation current Ie

32A

Rated control supply voltage Us at AC 60HZ

- - -V

Rated control supply voltage Us at AC 50HZ

- - -V

Rated operation power at AC-3, 230 V, 3-phase

-kW

Ambient temperature, upper operating limit

70°C

Rated operation power at AC-3, 400 V

15kW

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated control supply voltage Us at DC

24 - 24V

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Release class

CLASS 10

Rated operation current at AC-3, 400 V

32A

Rated conditional short-circuit current, type 2, 230 V

-A

Type of electrical connection of main circuit

Other

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Temperature compensated overload protection

Yes

Voltage type for actuating

DC

Rated conditional short-circuit current, type 2, 400 V

-A

Degree of protection (IP)

IP20

Supporting protocol for CAN

Yes

Supporting protocol for Data-Highway

No

Supporting protocol for TCP/IP

No

Supporting protocol for SUCONET

No

Supporting protocol for PROFINET IO

No

Supporting protocol for LON

No

Supporting protocol for DeviceNet

Yes

Supporting protocol for PROFINET CBA

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for PROFIBUS

Yes

Rail mounting possible

No

Supporting protocol for INTERBUS

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for ASI

Yes

Supporting protocol for EtherNet/IP

No

Supporting protocol for SERCOS

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for Modbus

Yes

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

Yes


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

LUCA32BL

Main Product Image

Details

  • Low-voltage industrial components
  • Trip block for power circuit-breaker
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Type of motor protection

Thermal/magnetic release

Short-circuit release function

Undelayed

Rated permanent current Iu

32A

External power supply required

Voltage type (operating voltage)

AC

Overload release current setting

8 .. 32A

Width

45mm

With ground fault protection function

Operating voltage at AC 60 Hz

690 .. 690V

Depth

60mm

Height

66mm

Operating voltage at AC 50 Hz

690 .. 690V

Voltage type of supply voltage

DC

Type of motor starter

Other

With short-circuit release

Rated operation current Ie

32A

Rated control supply voltage Us at AC 60HZ

- .. -V

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated operation power at AC-3, 230 V, 3-phase

-kW

Ambient temperature, upper operating limit

70°C

Rated operation power at AC-3, 400 V

15kW

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated control supply voltage Us at DC

24 .. 24V

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Release class

CLASS 10

Rated operation current at AC-3, 400 V

32A

Rated conditional short-circuit current, type 2, 230 V

-A

Type of electrical connection of main circuit

Other

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Temperature compensated overload protection

Voltage type for actuating

DC

Rated conditional short-circuit current, type 2, 400 V

-A

Degree of protection (IP)

IP20

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

Supporting protocol for LON

Supporting protocol for DeviceNet

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIBUS

Rail mounting possible

Supporting protocol for INTERBUS

Supporting protocol for INTERBUS-Safety

Supporting protocol for ASI

Supporting protocol for EtherNet/IP

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Modbus

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

From same serie