Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
With short-circuit release
Yes
Rated control supply voltage Us at AC 50HZ
110 - 240V
Rated operation power at AC-3, 400 V
7.5kW
Rated operation current Ie
4.5A
Rated operation power at AC-3, 230 V, 3-phase
7.5kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
4.5A
Rated power, 575 V, 60 Hz, 3-phase
15kW
Rated operation current at AC-3, 400 V
18A
Overload release current setting
4.5 - 18A
Voltage type for actuating
AC/DC
Type of motor starter
Other
Rated power, 460 V, 60 Hz, 3-phase
9kW
Number of auxiliary contacts as normally closed contact
0
Rated conditional short-circuit current, type 1, 600 Y/347 V
18A
Number of command positions
0
Ambient temperature, upper operating limit
70°C
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
Yes
Type of electrical connection of main circuit
Screw connection
Rated conditional short-circuit current, type 2, 400 V
18A
Rated conditional short-circuit current, type 2, 230 V
4.5A
With transformer
No
Number of auxiliary contacts as normally open contact
0
Temperature compensated overload protection
Yes
Rated control supply voltage Us at AC 60HZ
110 - 240V
Release class
CLASS 10
Rated control supply voltage Us at DC
110 - 220V
Suitable for emergency stop
No
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for PROFIBUS
No
Degree of protection (IP)
IP40
Supporting protocol for TCP/IP
No
External reset possible
No
Supporting protocol for INTERBUS
No
Number of indicator lights
0
Supporting protocol for ASI
No
Supporting protocol for CAN
No
With fuse
No
Supporting protocol for Modbus
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
45mm
Height
66mm
Depth
60mm
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for LON
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LUCA18FU

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
With short-circuit release
Rated control supply voltage Us at AC 50HZ
110 .. 240V
Rated operation power at AC-3, 400 V
7.5kW
Rated operation current Ie
4.5A
Rated operation power at AC-3, 230 V, 3-phase
7.5kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
4.5A
Rated power, 575 V, 60 Hz, 3-phase
15kW
Rated operation current at AC-3, 400 V
18A
Overload release current setting
4.5 .. 18A
Voltage type for actuating
AC/DC
Type of motor starter
Other
Rated power, 460 V, 60 Hz, 3-phase
9kW
Number of auxiliary contacts as normally closed contact
0
Rated conditional short-circuit current, type 1, 600 Y/347 V
18A
Number of command positions
0
Ambient temperature, upper operating limit
70°C
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
Type of electrical connection of main circuit
Screw connection
Rated conditional short-circuit current, type 2, 400 V
18A
Rated conditional short-circuit current, type 2, 230 V
4.5A
With transformer
Number of auxiliary contacts as normally open contact
0
Temperature compensated overload protection
Rated control supply voltage Us at AC 60HZ
110 .. 240V
Release class
CLASS 10
Rated control supply voltage Us at DC
110 .. 220V
Suitable for emergency stop
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for PROFIBUS
Degree of protection (IP)
IP40
Supporting protocol for TCP/IP
External reset possible
Supporting protocol for INTERBUS
Number of indicator lights
0
Supporting protocol for ASI
Supporting protocol for CAN
With fuse
Supporting protocol for Modbus
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
45mm
Height
66mm
Depth
60mm
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
From same serie