Aleta.hr

Details

  • Low-voltage industrial components
  • Tripping bloc for power circuit-breaker
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 60HZ

- - -V

Rated control supply voltage Us at AC 50HZ

- - -V

Overload release current setting

1.25 - 5A

Rated permanent current Iu

5A

Number of poles

3

Initial value of the undelayed short-circuit release - setting range

65A

End value adjustment range undelayed short-circuit release

65A

Voltage type for actuating

DC

Type of motor protection

Thermal/magnetic release

Rated control supply voltage Us at DC

24 - 24V

With ground fault protection function

Yes

Short-circuit release function

Undelayed

Type of motor starter

Other

With short-circuit release

Yes

Rated operation power at AC-3, 230 V, 3-phase

-kW

Rated operation power at AC-3, 400 V

1.5kW

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated operation current Ie

5A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 400 V

-A

Number of auxiliary contacts as normally open contact

0

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Rated operation current at AC-3, 400 V

5A

Ambient temperature, upper operating limit

70°C

Temperature compensated overload protection

Yes

Type of electrical connection of main circuit

Other

Number of auxiliary contacts as normally closed contact

0

Release class

CLASS 10

Degree of protection (IP)

IP20

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rail mounting possible

No

Supporting protocol for TCP/IP

No

Supporting protocol for Data-Highway

No

Supporting protocol for INTERBUS

No

Supporting protocol for CAN

Yes

Supporting protocol for ASI

Yes

Supporting protocol for Modbus

Yes

Supporting protocol for DeviceNet

Yes

Supporting protocol for PROFIBUS

Yes

Supporting protocol for PROFINET CBA

No

Supporting protocol for SERCOS

No

Supporting protocol for PROFINET IO

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for SUCONET

No

Supporting protocol for LON

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for other bus systems

Yes

Supporting protocol for SafetyBUS p

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

LUCA05BL

Main Product Image

Details

  • Low-voltage industrial components
  • Tripping bloc for power circuit-breaker
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 60HZ

- .. -V

Rated control supply voltage Us at AC 50HZ

- .. -V

Overload release current setting

1.25 .. 5A

Rated permanent current Iu

5A

Number of poles

3

Initial value of the undelayed short-circuit release - setting range

65A

End value adjustment range undelayed short-circuit release

65A

Voltage type for actuating

DC

Type of motor protection

Thermal/magnetic release

Rated control supply voltage Us at DC

24 .. 24V

With ground fault protection function

Short-circuit release function

Undelayed

Type of motor starter

Other

With short-circuit release

Rated operation power at AC-3, 230 V, 3-phase

-kW

Rated operation power at AC-3, 400 V

1.5kW

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated operation current Ie

5A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 400 V

-A

Number of auxiliary contacts as normally open contact

0

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Rated operation current at AC-3, 400 V

5A

Ambient temperature, upper operating limit

70°C

Temperature compensated overload protection

Type of electrical connection of main circuit

Other

Number of auxiliary contacts as normally closed contact

0

Release class

CLASS 10

Degree of protection (IP)

IP20

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rail mounting possible

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Supporting protocol for PROFINET CBA

Supporting protocol for SERCOS

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for other bus systems

Supporting protocol for SafetyBUS p

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.