Aleta.hr

Details

  • Low-voltage industrial components
  • Trip block for power circuit-breaker
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

5A

Voltage type of supply voltage

AC

Short-circuit release function

Undelayed

Number of poles

3

Depth

60mm

Voltage type (operating voltage)

AC

Operating voltage at AC 60 Hz

690 - 690V

Type of motor protection

Thermal/magnetic release

Width

45mm

Operating voltage at AC 50 Hz

690 - 690V

Height

66mm

External power supply required

Yes

With ground fault protection function

Yes

Overload release current setting

1.25 - 5A

Type of motor starter

Other

Rated operation power at AC-3, 400 V

1.5kW

Rated control supply voltage Us at AC 50HZ

24 - 24V

With short-circuit release

Yes

Temperature compensated overload protection

Yes

Release class

CLASS 10

Rated control supply voltage Us at AC 60HZ

24 - 24V

Rated control supply voltage Us at DC

- - -V

Rated power, 575 V, 60 Hz, 3-phase

-kW

Voltage type for actuating

AC

Ambient temperature, upper operating limit

70°C

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated operation power at AC-3, 230 V, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated operation current Ie

5A

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Rated operation current at AC-3, 400 V

5A

Type of electrical connection of main circuit

Other

Rail mounting possible

No

Degree of protection (IP)

IP20

Supporting protocol for PROFIBUS

Yes

Supporting protocol for ASI

Yes

Supporting protocol for DeviceNet

Yes

Supporting protocol for Data-Highway

No

Supporting protocol for Modbus

Yes

Supporting protocol for TCP/IP

No

Supporting protocol for PROFINET IO

No

Supporting protocol for INTERBUS

No

Supporting protocol for CAN

Yes

Supporting protocol for EtherNet/IP

No

Supporting protocol for PROFIsafe

No

Supporting protocol for LON

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for SUCONET

No

Supporting protocol for SERCOS

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for other bus systems

Yes

Supporting protocol for SafetyBUS p

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

LUCA05B

Main Product Image

Details

  • Low-voltage industrial components
  • Trip block for power circuit-breaker
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

5A

Voltage type of supply voltage

AC

Short-circuit release function

Undelayed

Number of poles

3

Depth

60mm

Voltage type (operating voltage)

AC

Operating voltage at AC 60 Hz

690 .. 690V

Type of motor protection

Thermal/magnetic release

Width

45mm

Operating voltage at AC 50 Hz

690 .. 690V

Height

66mm

External power supply required

With ground fault protection function

Overload release current setting

1.25 .. 5A

Type of motor starter

Other

Rated operation power at AC-3, 400 V

1.5kW

Rated control supply voltage Us at AC 50HZ

24 .. 24V

With short-circuit release

Temperature compensated overload protection

Release class

CLASS 10

Rated control supply voltage Us at AC 60HZ

24 .. 24V

Rated control supply voltage Us at DC

- .. -V

Rated power, 575 V, 60 Hz, 3-phase

-kW

Voltage type for actuating

AC

Ambient temperature, upper operating limit

70°C

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated operation power at AC-3, 230 V, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated operation current Ie

5A

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Rated operation current at AC-3, 400 V

5A

Type of electrical connection of main circuit

Other

Rail mounting possible

Degree of protection (IP)

IP20

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for TCP/IP

Supporting protocol for PROFINET IO

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Supporting protocol for LON

Supporting protocol for PROFINET CBA

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for other bus systems

Supporting protocol for SafetyBUS p

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.