Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- - -A
Temperature compensated overload protection
Yes
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
AC/DC
Rated power, 460 V, 60 Hz, 3-phase
5.5kW
With short-circuit release
Yes
Rated operation power at AC-3, 230 V, 3-phase
3kW
Rated control supply voltage Us at AC 60HZ
24 - 240V
Rated control supply voltage Us at AC 50HZ
24 - 240V
Rated operation current at AC-3, 400 V
12A
Rated operation power at AC-3, 400 V
5.5kW
Rated power, 575 V, 60 Hz, 3-phase
5.5kW
Rated operation current Ie
12A
Rated conditional short-circuit current, type 1, 600 Y/347 V
4000A
Rated conditional short-circuit current, type 2, 230 V
50000A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated conditional short-circuit current, type 2, 400 V
50000A
Number of auxiliary contacts as normally closed contact
1
Suitable for emergency stop
No
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000A
Ambient temperature, upper operating limit
70°C
Number of auxiliary contacts as normally open contact
1
Rail mounting possible
Yes
With transformer
No
External reset possible
No
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (IP)
IP20
Supporting protocol for ASI
No
Number of command positions
3
Supporting protocol for PROFIBUS
No
Supporting protocol for INTERBUS
No
With fuse
No
Rated control supply voltage Us at DC
24 - 220V
Supporting protocol for CAN
No
Number of indicator lights
0
Supporting protocol for TCP/IP
No
Type of electrical connection of main circuit
Screw connection
Supporting protocol for other bus systems
No
Width
45mm
Height
154mm
Depth
126mm
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET IO
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for DeviceNet
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Modbus
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for SERCOS
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for LON
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LUB12

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- .. -A
Temperature compensated overload protection
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
AC/DC
Rated power, 460 V, 60 Hz, 3-phase
5.5kW
With short-circuit release
Rated operation power at AC-3, 230 V, 3-phase
3kW
Rated control supply voltage Us at AC 60HZ
24 .. 240V
Rated control supply voltage Us at AC 50HZ
24 .. 240V
Rated operation current at AC-3, 400 V
12A
Rated operation power at AC-3, 400 V
5.5kW
Rated power, 575 V, 60 Hz, 3-phase
5.5kW
Rated operation current Ie
12A
Rated conditional short-circuit current, type 1, 600 Y/347 V
4000A
Rated conditional short-circuit current, type 2, 230 V
50000A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated conditional short-circuit current, type 2, 400 V
50000A
Number of auxiliary contacts as normally closed contact
1
Suitable for emergency stop
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000A
Ambient temperature, upper operating limit
70°C
Number of auxiliary contacts as normally open contact
1
Rail mounting possible
With transformer
External reset possible
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (IP)
IP20
Supporting protocol for ASI
Number of command positions
3
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
With fuse
Rated control supply voltage Us at DC
24 .. 220V
Supporting protocol for CAN
Number of indicator lights
0
Supporting protocol for TCP/IP
Type of electrical connection of main circuit
Screw connection
Supporting protocol for other bus systems
Width
45mm
Height
154mm
Depth
126mm
Supporting protocol for Data-Highway
Supporting protocol for PROFINET IO
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for DeviceNet
Supporting protocol for INTERBUS-Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET CBA
Supporting protocol for Modbus
Supporting protocol for SUCONET
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for LON
From same serie
We use cookies to enhance your experience.