Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- - -A
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Temperature compensated overload protection
Yes
Rated control supply voltage Us at DC
24 - 24V
Rated power, 460 V, 60 Hz, 3-phase
15kW
Type of motor starter
Reversing starter
Voltage type for actuating
DC
Rated operation current Ie
32A
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
4000A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated operation current at AC-3, 400 V
32A
Number of auxiliary contacts as normally open contact
1
Rated conditional short-circuit current, type 2, 400 V
50000A
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated operation power at AC-3, 230 V, 3-phase
7.5kW
Rated power, 575 V, 60 Hz, 3-phase
15kW
Number of auxiliary contacts as normally closed contact
1
Number of command positions
3
Suitable for emergency stop
No
With transformer
No
External reset possible
No
With short-circuit release
Yes
Supporting protocol for CAN
No
Ambient temperature, upper operating limit
70°C
Supporting protocol for PROFIBUS
No
Rated operation power at AC-3, 400 V
15kW
Supporting protocol for TCP/IP
No
Number of indicator lights
0
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
No
Supporting protocol for LON
No
Supporting protocol for ASI
No
Supporting protocol for PROFINET IO
No
Supporting protocol for INTERBUS
No
With fuse
No
Degree of protection (IP)
IP20
Supporting protocol for SUCONET
No
Coordination class according to IEC 60947-4-3
Class 2
Rail mounting possible
Yes
Supporting protocol for Data-Highway
No
Height
224mm
Depth
126mm
Supporting protocol for PROFINET CBA
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for SERCOS
No
Supporting protocol for other bus systems
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Foundation Fieldbus
No
Width
45mm
From same serie
LU2B32BL

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- .. -A
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Temperature compensated overload protection
Rated control supply voltage Us at DC
24 .. 24V
Rated power, 460 V, 60 Hz, 3-phase
15kW
Type of motor starter
Reversing starter
Voltage type for actuating
DC
Rated operation current Ie
32A
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
4000A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated operation current at AC-3, 400 V
32A
Number of auxiliary contacts as normally open contact
1
Rated conditional short-circuit current, type 2, 400 V
50000A
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated operation power at AC-3, 230 V, 3-phase
7.5kW
Rated power, 575 V, 60 Hz, 3-phase
15kW
Number of auxiliary contacts as normally closed contact
1
Number of command positions
3
Suitable for emergency stop
With transformer
External reset possible
With short-circuit release
Supporting protocol for CAN
Ambient temperature, upper operating limit
70°C
Supporting protocol for PROFIBUS
Rated operation power at AC-3, 400 V
15kW
Supporting protocol for TCP/IP
Number of indicator lights
0
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for ASI
Supporting protocol for PROFINET IO
Supporting protocol for INTERBUS
With fuse
Degree of protection (IP)
IP20
Supporting protocol for SUCONET
Coordination class according to IEC 60947-4-3
Class 2
Rail mounting possible
Supporting protocol for Data-Highway
Height
224mm
Depth
126mm
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for EtherNet/IP
Supporting protocol for SERCOS
Supporting protocol for other bus systems
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Width
45mm
From same serie
We use cookies to enhance your experience.