Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- - -V
Overload release current setting
- - -A
Temperature compensated overload protection
Yes
Rated control supply voltage Us at AC 60HZ
24 - 24V
Type of motor starter
Reversing starter
With short-circuit release
Yes
Rated operation current Ie
32A
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000A
Rated power, 460 V, 60 Hz, 3-phase
15kW
Number of auxiliary contacts as normally closed contact
1
Rated operation power at AC-3, 230 V, 3-phase
7.5kW
Rated operation power at AC-3, 400 V
15kW
Rated operation current at AC-3, 400 V
32A
Rated conditional short-circuit current, type 2, 230 V
50000A
With transformer
No
Ambient temperature, upper operating limit
70°C
Rail mounting possible
Yes
Rated conditional short-circuit current, type 1, 600 Y/347 V
4000A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of command positions
3
Type of electrical connection of main circuit
Screw connection
Rated control supply voltage Us at AC 50HZ
24 - 24V
Suitable for emergency stop
No
Number of auxiliary contacts as normally open contact
1
Voltage type for actuating
AC
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated power, 575 V, 60 Hz, 3-phase
15kW
External reset possible
No
Degree of protection (IP)
IP20
With fuse
No
Supporting protocol for PROFIBUS
No
Number of indicator lights
0
Supporting protocol for TCP/IP
No
Supporting protocol for CAN
No
Width
45mm
Coordination class according to IEC 60947-4-3
Class 2
Depth
126mm
Height
224mm
Supporting protocol for INTERBUS
No
Supporting protocol for Modbus
No
Supporting protocol for ASI
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
No
Supporting protocol for PROFINET IO
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Data-Highway
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SERCOS
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LU2B32B

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- .. -V
Overload release current setting
- .. -A
Temperature compensated overload protection
Rated control supply voltage Us at AC 60HZ
24 .. 24V
Type of motor starter
Reversing starter
With short-circuit release
Rated operation current Ie
32A
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000A
Rated power, 460 V, 60 Hz, 3-phase
15kW
Number of auxiliary contacts as normally closed contact
1
Rated operation power at AC-3, 230 V, 3-phase
7.5kW
Rated operation power at AC-3, 400 V
15kW
Rated operation current at AC-3, 400 V
32A
Rated conditional short-circuit current, type 2, 230 V
50000A
With transformer
Ambient temperature, upper operating limit
70°C
Rail mounting possible
Rated conditional short-circuit current, type 1, 600 Y/347 V
4000A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of command positions
3
Type of electrical connection of main circuit
Screw connection
Rated control supply voltage Us at AC 50HZ
24 .. 24V
Suitable for emergency stop
Number of auxiliary contacts as normally open contact
1
Voltage type for actuating
AC
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated power, 575 V, 60 Hz, 3-phase
15kW
External reset possible
Degree of protection (IP)
IP20
With fuse
Supporting protocol for PROFIBUS
Number of indicator lights
0
Supporting protocol for TCP/IP
Supporting protocol for CAN
Width
45mm
Coordination class according to IEC 60947-4-3
Class 2
Depth
126mm
Height
224mm
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for ASI
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for PROFINET IO
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for Data-Highway
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS-Safety
Supporting protocol for SERCOS
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
From same serie