Technical specifications

Overload release current setting

- - -A

Rated control supply voltage Us at AC 50HZ

- - -V

Rated control supply voltage Us at AC 60HZ

- - -V

Temperature compensated overload protection

Yes

With short-circuit release

Yes

Type of motor starter

Reversing starter

Rated operation current Ie

12A

Rated power, 460 V, 60 Hz, 3-phase

5.5kW

Rated control supply voltage Us at DC

24 - 24V

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated operation power at AC-3, 400 V

5.5kW

Rated operation current at AC-3, 400 V

12A

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 1, 600 Y/347 V

4000A

Rated conditional short-circuit current, type 1, 480 Y/277 V

10000A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated power, 575 V, 60 Hz, 3-phase

5.5kW

Number of auxiliary contacts as normally closed contact

1

Number of auxiliary contacts as normally open contact

1

Type of electrical connection of main circuit

Screw connection

Rail mounting possible

Yes

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Suitable for emergency stop

No

Number of command positions

3

Coordination class according to IEC 60947-4-3

Class 2

With transformer

No

External reset possible

No

With fuse

No

Number of indicator lights

0

Voltage type for actuating

DC

Ambient temperature, upper operating limit

70°C

Height

224mm

Depth

126mm

Degree of protection (IP)

IP20

Supporting protocol for TCP/IP

No

Supporting protocol for CAN

No

Supporting protocol for PROFIBUS

No

Supporting protocol for INTERBUS

No

Supporting protocol for ASI

No

Supporting protocol for Modbus

No

Supporting protocol for DeviceNet

No

Supporting protocol for PROFINET IO

No

Supporting protocol for Data-Highway

No

Supporting protocol for SUCONET

No

Supporting protocol for LON

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for SERCOS

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for PROFIsafe

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for other bus systems

No

Supporting protocol for INTERBUS-Safety

No

Width

45mm


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

LU2B12BL

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated control supply voltage Us at AC 60HZ

- .. -V

Temperature compensated overload protection

With short-circuit release

Type of motor starter

Reversing starter

Rated operation current Ie

12A

Rated power, 460 V, 60 Hz, 3-phase

5.5kW

Rated control supply voltage Us at DC

24 .. 24V

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated operation power at AC-3, 400 V

5.5kW

Rated operation current at AC-3, 400 V

12A

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 1, 600 Y/347 V

4000A

Rated conditional short-circuit current, type 1, 480 Y/277 V

10000A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated power, 575 V, 60 Hz, 3-phase

5.5kW

Number of auxiliary contacts as normally closed contact

1

Number of auxiliary contacts as normally open contact

1

Type of electrical connection of main circuit

Screw connection

Rail mounting possible

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Suitable for emergency stop

Number of command positions

3

Coordination class according to IEC 60947-4-3

Class 2

With transformer

External reset possible

With fuse

Number of indicator lights

0

Voltage type for actuating

DC

Ambient temperature, upper operating limit

70°C

Height

224mm

Depth

126mm

Degree of protection (IP)

IP20

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for PROFINET IO

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for PROFINET CBA

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for other bus systems

Supporting protocol for INTERBUS-Safety