Aleta.hr
Main Product Image

LU2B12B

Code: 1704465

ManufacturerRAZNO
Catalog numberLU2B12B
Type
EAN code3389110362947

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at DC

- - -V

Overload release current setting

- - -A

Temperature compensated overload protection

Yes

Type of motor starter

Reversing starter

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated control supply voltage Us at AC 50HZ

24 - 24V

Voltage type for actuating

AC

Rated operation power at AC-3, 400 V

5.5kW

Rated power, 460 V, 60 Hz, 3-phase

5.5kW

Rated operation power at AC-3, 230 V, 3-phase

3kW

Number of auxiliary contacts as normally open contact

1

Rated operation current Ie

12A

Rated conditional short-circuit current, type 2, 400 V

50000A

Suitable for emergency stop

No

Rated power, 575 V, 60 Hz, 3-phase

5.5kW

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

No

Number of auxiliary contacts as normally closed contact

1

Coordination class according to IEC 60947-4-3

Class 2

Ambient temperature, upper operating limit

70°C

Rated operation current at AC-3, 400 V

12A

Number of command positions

3

With short-circuit release

Yes

Degree of protection (IP)

IP20

Supporting protocol for TCP/IP

No

Rated conditional short-circuit current, type 1, 480 Y/277 V

10000A

Rail mounting possible

Yes

With fuse

No

Rated conditional short-circuit current, type 1, 600 Y/347 V

4000A

Supporting protocol for Modbus

No

External reset possible

No

Supporting protocol for ASI

No

Supporting protocol for PROFIBUS

No

Supporting protocol for INTERBUS

No

Supporting protocol for PROFINET IO

No

Supporting protocol for CAN

No

Supporting protocol for INTERBUS-Safety

No

Height

224mm

Supporting protocol for DeviceNet Safety

No

Supporting protocol for SUCONET

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for PROFIsafe

No

Number of indicator lights

0

Supporting protocol for LON

No

Rated control supply voltage Us at AC 60HZ

24 - 24V

Supporting protocol for SERCOS

No

Width

45mm

Supporting protocol for other bus systems

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for Data-Highway

No

Supporting protocol for DeviceNet

No

Depth

126mm


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

LU2B12B

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at DC

- .. -V

Overload release current setting

- .. -A

Temperature compensated overload protection

Type of motor starter

Reversing starter

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated control supply voltage Us at AC 50HZ

24 .. 24V

Voltage type for actuating

AC

Rated operation power at AC-3, 400 V

5.5kW

Rated power, 460 V, 60 Hz, 3-phase

5.5kW

Rated operation power at AC-3, 230 V, 3-phase

3kW

Number of auxiliary contacts as normally open contact

1

Rated operation current Ie

12A

Rated conditional short-circuit current, type 2, 400 V

50000A

Suitable for emergency stop

Rated power, 575 V, 60 Hz, 3-phase

5.5kW

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

Number of auxiliary contacts as normally closed contact

1

Coordination class according to IEC 60947-4-3

Class 2

Ambient temperature, upper operating limit

70°C

Rated operation current at AC-3, 400 V

12A

Number of command positions

3

With short-circuit release

Degree of protection (IP)

IP20

Supporting protocol for TCP/IP

Rated conditional short-circuit current, type 1, 480 Y/277 V

10000A

Rail mounting possible

With fuse

Rated conditional short-circuit current, type 1, 600 Y/347 V

4000A

Supporting protocol for Modbus

External reset possible

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for PROFINET IO

Supporting protocol for CAN

Supporting protocol for INTERBUS-Safety

Height

224mm

Supporting protocol for DeviceNet Safety

Supporting protocol for SUCONET

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Number of indicator lights

0

Supporting protocol for LON

Rated control supply voltage Us at AC 60HZ

24 .. 24V

Supporting protocol for SERCOS

Width

45mm

Supporting protocol for other bus systems

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Depth

126mm

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.