Technical specifications
Rated control supply voltage Us at DC
- - -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
With short-circuit release
No
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 50HZ
230 - 230V
Rated control supply voltage Us at AC 60HZ
230 - 230V
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rated operation power at AC-3, 400 V
3kW
Overload release current setting
5.5 - 8A
Voltage type for actuating
AC
Rated operation current Ie
8A
Rated power, 460 V, 60 Hz, 3-phase
3kW
Rated power, 575 V, 60 Hz, 3-phase
4kW
Temperature compensated overload protection
Yes
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
No
Release class
CLASS 10 A
Number of auxiliary contacts as normally open contact
0
Ambient temperature, upper operating limit
40°C
With transformer
No
Number of command positions
2
External reset possible
Yes
Number of indicator lights
1
Supporting protocol for CAN
No
Supporting protocol for TCP/IP
No
Suitable for emergency stop
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Rated operation current at AC-3, 400 V
8A
Supporting protocol for PROFIBUS
No
With fuse
No
Supporting protocol for DeviceNet
No
Degree of protection (IP)
IP65
Supporting protocol for Modbus
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Data-Highway
No
Depth
108mm
Supporting protocol for EtherNet/IP
No
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for other bus systems
No
Height
160mm
Width
78mm
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SafetyBUS p
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LE1M35P714

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- .. -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
With short-circuit release
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rated control supply voltage Us at AC 60HZ
230 .. 230V
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rated operation power at AC-3, 400 V
3kW
Overload release current setting
5.5 .. 8A
Voltage type for actuating
AC
Rated operation current Ie
8A
Rated power, 460 V, 60 Hz, 3-phase
3kW
Rated power, 575 V, 60 Hz, 3-phase
4kW
Temperature compensated overload protection
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
Release class
CLASS 10 A
Number of auxiliary contacts as normally open contact
0
Ambient temperature, upper operating limit
40°C
With transformer
Number of command positions
2
External reset possible
Number of indicator lights
1
Supporting protocol for CAN
Supporting protocol for TCP/IP
Suitable for emergency stop
Supporting protocol for INTERBUS
Supporting protocol for ASI
Rated operation current at AC-3, 400 V
8A
Supporting protocol for PROFIBUS
With fuse
Supporting protocol for DeviceNet
Degree of protection (IP)
IP65
Supporting protocol for Modbus
Supporting protocol for PROFINET IO
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for Data-Highway
Depth
108mm
Supporting protocol for EtherNet/IP
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for Foundation Fieldbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for other bus systems
Height
160mm
Width
78mm
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
From same serie
We use cookies to enhance your experience.