Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- - -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Rated control supply voltage Us at AC 60HZ
230 - 230V
Rated operation current Ie
5.5A
Overload release current setting
3.7 - 5.5A
Rated operation current at AC-3, 400 V
5.5A
Number of auxiliary contacts as normally open contact
0
Rated control supply voltage Us at AC 50HZ
230 - 230V
Rail mounting possible
No
Type of electrical connection of main circuit
Screw connection
Temperature compensated overload protection
Yes
Ambient temperature, upper operating limit
40°C
Degree of protection (IP)
IP65
With short-circuit release
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for Modbus
No
Supporting protocol for PROFINET IO
No
Rated operation power at AC-3, 230 V, 3-phase
1.1kW
Release class
CLASS 10 A
Type of motor starter
Direct online starter (DOL)
Supporting protocol for LON
No
Number of auxiliary contacts as normally closed contact
0
Number of indicator lights
1
Rated power, 575 V, 60 Hz, 3-phase
3kW
With transformer
No
With fuse
No
Supporting protocol for SUCONET
No
External reset possible
Yes
Supporting protocol for PROFINET CBA
No
Suitable for emergency stop
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for Data-Highway
No
Voltage type for actuating
AC
Rated operation power at AC-3, 400 V
2.2kW
Supporting protocol for TCP/IP
No
Number of command positions
2
Supporting protocol for DeviceNet
No
Supporting protocol for PROFIBUS
No
Rated power, 460 V, 60 Hz, 3-phase
2.2kW
Depth
108mm
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for DeviceNet Safety
No
Width
78mm
Supporting protocol for EtherNet/IP
No
Supporting protocol for INTERBUS-Safety
No
Height
160mm
Supporting protocol for SafetyBUS p
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
From same serie
LE1M35P712

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- .. -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Rated control supply voltage Us at AC 60HZ
230 .. 230V
Rated operation current Ie
5.5A
Overload release current setting
3.7 .. 5.5A
Rated operation current at AC-3, 400 V
5.5A
Number of auxiliary contacts as normally open contact
0
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rail mounting possible
Type of electrical connection of main circuit
Screw connection
Temperature compensated overload protection
Ambient temperature, upper operating limit
40°C
Degree of protection (IP)
IP65
With short-circuit release
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for Modbus
Supporting protocol for PROFINET IO
Rated operation power at AC-3, 230 V, 3-phase
1.1kW
Release class
CLASS 10 A
Type of motor starter
Direct online starter (DOL)
Supporting protocol for LON
Number of auxiliary contacts as normally closed contact
0
Number of indicator lights
1
Rated power, 575 V, 60 Hz, 3-phase
3kW
With transformer
With fuse
Supporting protocol for SUCONET
External reset possible
Supporting protocol for PROFINET CBA
Suitable for emergency stop
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for Data-Highway
Voltage type for actuating
AC
Rated operation power at AC-3, 400 V
2.2kW
Supporting protocol for TCP/IP
Number of command positions
2
Supporting protocol for DeviceNet
Supporting protocol for PROFIBUS
Rated power, 460 V, 60 Hz, 3-phase
2.2kW
Depth
108mm
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for DeviceNet Safety
Width
78mm
Supporting protocol for EtherNet/IP
Supporting protocol for INTERBUS-Safety
Height
160mm
Supporting protocol for SafetyBUS p
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
From same serie
We use cookies to enhance your experience.