Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- - -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Rated control supply voltage Us at AC 60HZ
220 - 220V
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 50HZ
220 - 220V
Rated operation power at AC-3, 400 V
7.5kW
Rated power, 460 V, 60 Hz, 3-phase
7.5kW
With short-circuit release
No
Rated operation current Ie
16A
Rated operation power at AC-3, 230 V, 3-phase
3.7kW
Voltage type for actuating
AC
Number of auxiliary contacts as normally open contact
0
Rated operation current at AC-3, 400 V
16A
Overload release current setting
12 - 16A
Temperature compensated overload protection
Yes
Type of electrical connection of main circuit
Screw connection
Rated power, 575 V, 60 Hz, 3-phase
9kW
Ambient temperature, upper operating limit
40°C
Release class
CLASS 10 A
Rail mounting possible
No
With transformer
No
Number of command positions
1
Suitable for emergency stop
No
Supporting protocol for TCP/IP
No
Number of indicator lights
0
Supporting protocol for INTERBUS
No
Supporting protocol for CAN
No
Degree of protection (IP)
IP65
With fuse
No
Supporting protocol for ASI
No
External reset possible
No
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for PROFIBUS
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for Modbus
No
Supporting protocol for LON
No
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
No
Supporting protocol for PROFINET IO
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Supporting protocol for PROFIsafe
No
Depth
108mm
Height
160mm
Width
78mm
From same serie
LE1M35M722

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- .. -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Rated control supply voltage Us at AC 60HZ
220 .. 220V
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 50HZ
220 .. 220V
Rated operation power at AC-3, 400 V
7.5kW
Rated power, 460 V, 60 Hz, 3-phase
7.5kW
With short-circuit release
Rated operation current Ie
16A
Rated operation power at AC-3, 230 V, 3-phase
3.7kW
Voltage type for actuating
AC
Number of auxiliary contacts as normally open contact
0
Rated operation current at AC-3, 400 V
16A
Overload release current setting
12 .. 16A
Temperature compensated overload protection
Type of electrical connection of main circuit
Screw connection
Rated power, 575 V, 60 Hz, 3-phase
9kW
Ambient temperature, upper operating limit
40°C
Release class
CLASS 10 A
Rail mounting possible
With transformer
Number of command positions
1
Suitable for emergency stop
Supporting protocol for TCP/IP
Number of indicator lights
0
Supporting protocol for INTERBUS
Supporting protocol for CAN
Degree of protection (IP)
IP65
With fuse
Supporting protocol for ASI
External reset possible
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for PROFIBUS
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for Modbus
Supporting protocol for LON
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for PROFINET IO
Supporting protocol for EtherNet/IP
Supporting protocol for SERCOS
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Supporting protocol for PROFIsafe
Depth
108mm
Height
160mm
Width
78mm
From same serie