

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- - -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Voltage type for actuating
AC
Rated control supply voltage Us at AC 50HZ
220 - 220V
With short-circuit release
No
Rated operation power at AC-3, 400 V
2.2kW
Rated power, 460 V, 60 Hz, 3-phase
2.2kW
Rated operation power at AC-3, 230 V, 3-phase
1.1kW
Rated operation current Ie
5.5A
Type of motor starter
Direct online starter (DOL)
Overload release current setting
3.7 - 5.5A
Rated power, 575 V, 60 Hz, 3-phase
3kW
Number of auxiliary contacts as normally open contact
0
Rated control supply voltage Us at AC 60HZ
220 - 220V
Ambient temperature, upper operating limit
40°C
Number of auxiliary contacts as normally closed contact
0
Release class
CLASS 10 A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Temperature compensated overload protection
Yes
Rail mounting possible
No
Type of electrical connection of main circuit
Screw connection
With transformer
No
Number of indicator lights
1
Number of command positions
2
Suitable for emergency stop
No
External reset possible
Yes
With fuse
No
Degree of protection (IP)
IP65
Supporting protocol for Modbus
No
Supporting protocol for CAN
No
Supporting protocol for Data-Highway
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for DeviceNet
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS-Safety
No
Rated operation current at AC-3, 400 V
5.5A
Supporting protocol for AS-Interface Safety at Work
No
Depth
108mm
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
78mm
Height
160mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LE1M35M712

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- .. -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Voltage type for actuating
AC
Rated control supply voltage Us at AC 50HZ
220 .. 220V
With short-circuit release
Rated operation power at AC-3, 400 V
2.2kW
Rated power, 460 V, 60 Hz, 3-phase
2.2kW
Rated operation power at AC-3, 230 V, 3-phase
1.1kW
Rated operation current Ie
5.5A
Type of motor starter
Direct online starter (DOL)
Overload release current setting
3.7 .. 5.5A
Rated power, 575 V, 60 Hz, 3-phase
3kW
Number of auxiliary contacts as normally open contact
0
Rated control supply voltage Us at AC 60HZ
220 .. 220V
Ambient temperature, upper operating limit
40°C
Number of auxiliary contacts as normally closed contact
0
Release class
CLASS 10 A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Temperature compensated overload protection
Rail mounting possible
Type of electrical connection of main circuit
Screw connection
With transformer
Number of indicator lights
1
Number of command positions
2
Suitable for emergency stop
External reset possible
With fuse
Degree of protection (IP)
IP65
Supporting protocol for Modbus
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for DeviceNet
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Rated operation current at AC-3, 400 V
5.5A
Supporting protocol for AS-Interface Safety at Work
Depth
108mm
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
78mm
Height
160mm
From same serie
We use cookies to enhance your experience.