

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP65
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Screw connection
Rated control supply voltage Us at DC
0 - 0V
Overload release current setting
0.8 - 1.2A
Rated control supply voltage Us at AC 60HZ
220 - 220V
Rated control supply voltage Us at AC 50HZ
220 - 220V
Voltage type for actuating
AC
Rated operation power at AC-3, 400 V
0.37kW
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for DeviceNet
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
No
Supporting protocol for ASI
No
Supporting protocol for TCP/IP
No
Supporting protocol for CAN
No
Supporting protocol for PROFIBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for other bus systems
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for INTERBUS
No
Rail mounting possible
No
Rated operation current Ie
0A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation current at AC-3, 400 V
1.2A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
0.18kW
Ambient temperature, upper operating limit
40°C
Rated conditional short-circuit current, type 2, 400 V
0A
With short-circuit release
No
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Type of motor starter
Direct online starter (DOL)
Rated conditional short-circuit current, type 2, 230 V
0A
Temperature compensated overload protection
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LE1M35M706

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP65
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Screw connection
Rated control supply voltage Us at DC
0 .. 0V
Overload release current setting
0.8 .. 1.2A
Rated control supply voltage Us at AC 60HZ
220 .. 220V
Rated control supply voltage Us at AC 50HZ
220 .. 220V
Voltage type for actuating
AC
Rated operation power at AC-3, 400 V
0.37kW
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Supporting protocol for Modbus
Supporting protocol for DeviceNet Safety
Supporting protocol for DeviceNet
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Supporting protocol for ASI
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Supporting protocol for other bus systems
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for INTERBUS
Rail mounting possible
Rated operation current Ie
0A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation current at AC-3, 400 V
1.2A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
0.18kW
Ambient temperature, upper operating limit
40°C
Rated conditional short-circuit current, type 2, 400 V
0A
With short-circuit release
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Type of motor starter
Direct online starter (DOL)
Rated conditional short-circuit current, type 2, 230 V
0A
Temperature compensated overload protection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
From same serie
We use cookies to enhance your experience.