Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- - -A

Rated control supply voltage Us at DC

- - -V

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Temperature compensated overload protection

No

With short-circuit release

No

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at AC 50HZ

230 - 230V

Voltage type for actuating

AC

Rated control supply voltage Us at AC 60HZ

230 - 230V

Rated operation power at AC-3, 400 V

5.5kW

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated power, 460 V, 60 Hz, 3-phase

5.5kW

Number of auxiliary contacts as normally open contact

0

Rated operation current at AC-3, 400 V

12A

Rated operation current Ie

12A

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rated power, 575 V, 60 Hz, 3-phase

7.5kW

With transformer

No

Rail mounting possible

No

Number of command positions

1

Ambient temperature, upper operating limit

40°C

Number of indicator lights

0

External reset possible

No

Degree of protection (IP)

IP65

With fuse

No

Supporting protocol for TCP/IP

No

Supporting protocol for ASI

No

Suitable for emergency stop

No

Supporting protocol for INTERBUS

No

Supporting protocol for Data-Highway

No

Supporting protocol for Modbus

No

Supporting protocol for LON

No

Supporting protocol for PROFIBUS

No

Supporting protocol for CAN

No

Supporting protocol for DeviceNet

No

Supporting protocol for SUCONET

No

Supporting protocol for PROFINET IO

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for SafetyBUS p

No

Width

88mm

Supporting protocol for other bus systems

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SERCOS

No

Depth

128.5mm

Supporting protocol for DeviceNet Safety

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for Foundation Fieldbus

No

Height

166mm

Supporting protocol for EtherNet/IP

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

LE1D12P7

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Rated control supply voltage Us at DC

- .. -V

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Temperature compensated overload protection

With short-circuit release

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Voltage type for actuating

AC

Rated control supply voltage Us at AC 60HZ

230 .. 230V

Rated operation power at AC-3, 400 V

5.5kW

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated power, 460 V, 60 Hz, 3-phase

5.5kW

Number of auxiliary contacts as normally open contact

0

Rated operation current at AC-3, 400 V

12A

Rated operation current Ie

12A

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rated power, 575 V, 60 Hz, 3-phase

7.5kW

With transformer

Rail mounting possible

Number of command positions

1

Ambient temperature, upper operating limit

40°C

Number of indicator lights

0

External reset possible

Degree of protection (IP)

IP65

With fuse

Supporting protocol for TCP/IP

Supporting protocol for ASI

Suitable for emergency stop

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for LON

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Width

88mm

Supporting protocol for other bus systems

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SERCOS

Depth

128.5mm

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Height

166mm

Supporting protocol for EtherNet/IP

From same serie