Aleta.hr
Main Product Image

GB2CB12

Code: 1698170

ManufacturerRAZNO
Catalog numberGB2CB12
Type
EAN code3389110214697

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

74mm

Release characteristic

Other

Rated voltage

250V

Number of protected poles

1

Number of poles (total)

1

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

1.5kA

Rated insulation voltage Ui

250V

Flush-mounted installation

No

Current limiting class

3

Frequency

50 - 60Hz

Concurrently switching neutral conductor

No

Additional equipment possible

No

Over voltage category

3

Pollution degree

2

Width in number of modular spacings

1

Connectable conductor cross section multi-wired

0.75 - 4mm²

Rated current

6A

Degree of protection (IP)

IP20

Explosion-proof

No

Connectable conductor cross section solid-core

0.75 - 6mm²

Ambient temperature during operating

-20 - 60°C


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GB2CB12

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

74mm

Release characteristic

Other

Rated voltage

250V

Number of protected poles

1

Number of poles (total)

1

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

1.5kA

Rated insulation voltage Ui

250V

Flush-mounted installation

Current limiting class

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Additional equipment possible

Over voltage category

3

Pollution degree

2

Width in number of modular spacings

1

Connectable conductor cross section multi-wired

0.75 .. 4mm²

Rated current

6A

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 6mm²

Ambient temperature during operating

-20 .. 60°C

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.