Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 - 480V
Max. output frequency
500Hz
Max. output at linear load at rated output voltage
3kW
Number of phases output
3
Nominal output current I2N
7.2A
Max. output voltage
480V
Application in industrial area permitted
Yes
With control element
Yes
Number of digital inputs
6
Number of digital outputs
0
Application in domestic- and commercial area permitted
Yes
Supporting protocol for TCP/IP
Yes
Supporting protocol for PROFIBUS
Yes
Mains frequency
50/60 Hz
Relative symmetric net frequency tolerance
5%
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for KNX
No
Supporting protocol for LON
No
Max. output at quadratic load at rated output voltage
3kW
Supporting protocol for SERCOS
No
Relative symmetric net voltage tolerance
10%
Supporting protocol for PROFINET CBA
No
Supporting protocol for ASI
No
Number of phases input
3
Number of analogue inputs
3
Supporting protocol for PROFINET IO
Yes
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Supporting protocol for AS-Interface Safety at Work
No
Number of analogue outputs
2
Supporting protocol for Modbus
Yes
Number of interfaces PROFINET
0
Supporting protocol for INTERBUS-Safety
No
Number of HW-interfaces RS-485
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Supporting protocol for Data-Highway
No
Number of HW-interfaces RS-232
0
Supporting protocol for DeviceNet
Yes
Supporting protocol for EtherNet/IP
Yes
Number of HW-interfaces USB
0
Supporting protocol for SUCONET
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for other bus systems
No
Number of HW-interfaces RS-422
0
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces serial TTY
0
Supporting protocol for BACnet
No
With optical interface
Yes
With PC connection
No
Integrated breaking resistance
No
4-quadrant operation possible
Yes
Type of converter
U converter
Degree of protection (IP)
IP21
Height
350mm
Width
144mm
Depth
203mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV630U30N4
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 .. 480V
Max. output frequency
500Hz
Max. output at linear load at rated output voltage
3kW
Number of phases output
3
Nominal output current I2N
7.2A
Max. output voltage
480V
Application in industrial area permitted
With control element
Number of digital inputs
6
Number of digital outputs
0
Application in domestic- and commercial area permitted
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Mains frequency
50/60 Hz
Relative symmetric net frequency tolerance
5%
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for KNX
Supporting protocol for LON
Max. output at quadratic load at rated output voltage
3kW
Supporting protocol for SERCOS
Relative symmetric net voltage tolerance
10%
Supporting protocol for PROFINET CBA
Supporting protocol for ASI
Number of phases input
3
Number of analogue inputs
3
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Supporting protocol for AS-Interface Safety at Work
Number of analogue outputs
2
Supporting protocol for Modbus
Number of interfaces PROFINET
0
Supporting protocol for INTERBUS-Safety
Number of HW-interfaces RS-485
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Supporting protocol for Data-Highway
Number of HW-interfaces RS-232
0
Supporting protocol for DeviceNet
Supporting protocol for EtherNet/IP
Number of HW-interfaces USB
0
Supporting protocol for SUCONET
Supporting protocol for Foundation Fieldbus
Supporting protocol for other bus systems
Number of HW-interfaces RS-422
0
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces serial TTY
0
Supporting protocol for BACnet
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP21
Height
350mm
Width
144mm
Depth
203mm
From same serie
We use cookies to enhance your experience.