Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains frequency
50/60 Hz
Max. output frequency
500Hz
Number of phases output
3
Mains voltage
380 - 480V
Nominal output current I2N
2.2A
Max. output at quadratic load at rated output voltage
0.75kW
Max. output voltage
480V
Number of analogue outputs
2
With control element
Yes
Max. output at linear load at rated output voltage
0.75kW
Number of phases input
3
Number of analogue inputs
3
Number of digital inputs
6
Number of digital outputs
0
Relative symmetric net frequency tolerance
5%
Relative symmetric net voltage tolerance
10%
Application in industrial area permitted
Yes
Supporting protocol for CAN
No
Supporting protocol for TCP/IP
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for KNX
No
Supporting protocol for Data-Highway
No
Supporting protocol for ASI
No
Application in domestic- and commercial area permitted
Yes
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for LON
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for Foundation Fieldbus
No
Number of HW-interfaces RS-485
1
Number of HW-interfaces parallel
0
Supporting protocol for Modbus
Yes
Supporting protocol for other bus systems
No
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces other
0
Supporting protocol for PROFINET IO
Yes
Number of interfaces PROFINET
0
Number of HW-interfaces serial TTY
0
Supporting protocol for BACnet
No
Number of HW-interfaces RS-422
0
Supporting protocol for PROFINET CBA
No
With optical interface
Yes
With PC connection
No
Integrated breaking resistance
No
4-quadrant operation possible
Yes
Type of converter
U converter
Degree of protection (IP)
IP21
Height
350mm
Depth
203mm
Width
144mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV630U07N4
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains frequency
50/60 Hz
Max. output frequency
500Hz
Number of phases output
3
Mains voltage
380 .. 480V
Nominal output current I2N
2.2A
Max. output at quadratic load at rated output voltage
0.75kW
Max. output voltage
480V
Number of analogue outputs
2
With control element
Max. output at linear load at rated output voltage
0.75kW
Number of phases input
3
Number of analogue inputs
3
Number of digital inputs
6
Number of digital outputs
0
Relative symmetric net frequency tolerance
5%
Relative symmetric net voltage tolerance
10%
Application in industrial area permitted
Supporting protocol for CAN
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for KNX
Supporting protocol for Data-Highway
Supporting protocol for ASI
Application in domestic- and commercial area permitted
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for DeviceNet Safety
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for Foundation Fieldbus
Number of HW-interfaces RS-485
1
Number of HW-interfaces parallel
0
Supporting protocol for Modbus
Supporting protocol for other bus systems
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces other
0
Supporting protocol for PROFINET IO
Number of interfaces PROFINET
0
Number of HW-interfaces serial TTY
0
Supporting protocol for BACnet
Number of HW-interfaces RS-422
0
Supporting protocol for PROFINET CBA
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP21
Height
350mm
Depth
203mm
Width
144mm
From same serie
We use cookies to enhance your experience.