Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Max. output at linear load at rated output voltage
22kW
Number of analogue outputs
2
Max. output voltage
480V
Max. output at quadratic load at rated output voltage
22kW
Number of phases output
3
Number of phases input
3
Mains voltage
380 - 480V
Supporting protocol for ASI
No
Relative symmetric net voltage tolerance
10%
Supporting protocol for KNX
No
Number of analogue inputs
3
Application in industrial area permitted
Yes
Supporting protocol for TCP/IP
Yes
Supporting protocol for SUCONET
No
Number of digital inputs
6
With control element
Yes
Supporting protocol for CAN
No
Supporting protocol for DeviceNet
Yes
Relative symmetric net frequency tolerance
5%
Nominal output current I2N
46.3A
Max. output frequency
500Hz
Supporting protocol for Modbus
Yes
Application in domestic- and commercial area permitted
Yes
Supporting protocol for PROFIBUS
Yes
Number of digital outputs
0
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS
No
Mains frequency
50/60 Hz
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for AS-Interface Safety at Work
No
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Supporting protocol for BACnet
No
Supporting protocol for other bus systems
No
With optical interface
Yes
Supporting protocol for INTERBUS-Safety
No
With PC connection
No
Type of converter
U converter
Integrated breaking resistance
No
4-quadrant operation possible
Yes
Degree of protection (IP)
IP21
Height
546mm
Width
211mm
Depth
232mm
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV630D22N4
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Max. output at linear load at rated output voltage
22kW
Number of analogue outputs
2
Max. output voltage
480V
Max. output at quadratic load at rated output voltage
22kW
Number of phases output
3
Number of phases input
3
Mains voltage
380 .. 480V
Supporting protocol for ASI
Relative symmetric net voltage tolerance
10%
Supporting protocol for KNX
Number of analogue inputs
3
Application in industrial area permitted
Supporting protocol for TCP/IP
Supporting protocol for SUCONET
Number of digital inputs
6
With control element
Supporting protocol for CAN
Supporting protocol for DeviceNet
Relative symmetric net frequency tolerance
5%
Nominal output current I2N
46.3A
Max. output frequency
500Hz
Supporting protocol for Modbus
Application in domestic- and commercial area permitted
Supporting protocol for PROFIBUS
Number of digital outputs
0
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Mains frequency
50/60 Hz
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
Supporting protocol for DeviceNet Safety
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Supporting protocol for AS-Interface Safety at Work
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Supporting protocol for BACnet
Supporting protocol for other bus systems
With optical interface
Supporting protocol for INTERBUS-Safety
With PC connection
Type of converter
U converter
Integrated breaking resistance
4-quadrant operation possible
Degree of protection (IP)
IP21
Height
546mm
Width
211mm
Depth
232mm
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1