Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Max. output voltage
480V
Relative symmetric net frequency tolerance
5%
Max. output at quadratic load at rated output voltage
75kW
Mains voltage
380 - 480V
Supporting protocol for CAN
No
Number of digital outputs
0
Application in domestic- and commercial area permitted
Yes
Supporting protocol for ASI
No
Mains frequency
50/60 Hz
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Number of analogue inputs
2
Supporting protocol for KNX
No
Supporting protocol for LON
Yes
Max. output frequency
200Hz
Supporting protocol for SUCONET
No
Number of phases output
3
Number of analogue outputs
1
Application in industrial area permitted
Yes
Relative symmetric net voltage tolerance
10%
Supporting protocol for INTERBUS
No
Max. output at linear load at rated output voltage
75kW
Number of phases input
3
Number of digital inputs
3
Supporting protocol for Modbus
Yes
With control element
Yes
Nominal output current I2N
160A
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
With optical interface
No
Integrated breaking resistance
No
With PC connection
Yes
4-quadrant operation possible
No
Type of converter
U converter
Degree of protection (IP)
IP55
Height
1000mm
Width
362mm
Depth
364mm
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFIsafe
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
No
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for other bus systems
Yes
Number of interfaces PROFINET
0
Supporting protocol for AS-Interface Safety at Work
No
Number of HW-interfaces RS-485
1
Number of HW-interfaces RS-232
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces other
0
Number of HW-interfaces USB
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV212WD75N4C
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Max. output voltage
480V
Relative symmetric net frequency tolerance
5%
Max. output at quadratic load at rated output voltage
75kW
Mains voltage
380 .. 480V
Supporting protocol for CAN
Number of digital outputs
0
Application in domestic- and commercial area permitted
Supporting protocol for ASI
Mains frequency
50/60 Hz
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Number of analogue inputs
2
Supporting protocol for KNX
Supporting protocol for LON
Max. output frequency
200Hz
Supporting protocol for SUCONET
Number of phases output
3
Number of analogue outputs
1
Application in industrial area permitted
Relative symmetric net voltage tolerance
10%
Supporting protocol for INTERBUS
Max. output at linear load at rated output voltage
75kW
Number of phases input
3
Number of digital inputs
3
Supporting protocol for Modbus
With control element
Nominal output current I2N
160A
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
With optical interface
Integrated breaking resistance
With PC connection
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP55
Height
1000mm
Width
362mm
Depth
364mm
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for PROFIsafe
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for BACnet
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for other bus systems
Number of interfaces PROFINET
0
Supporting protocol for AS-Interface Safety at Work
Number of HW-interfaces RS-485
1
Number of HW-interfaces RS-232
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces other
0
Number of HW-interfaces USB
0
From same serie
We use cookies to enhance your experience.