Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains frequency
50/60 Hz
Mains voltage
380 - 480V
Number of phases input
3
Nominal output current I2N
116A
Max. output at quadratic load at rated output voltage
55kW
Max. output frequency
200Hz
Number of analogue outputs
1
Relative symmetric net voltage tolerance
10%
Application in industrial area permitted
Yes
Number of phases output
3
Max. output at linear load at rated output voltage
55kW
Number of analogue inputs
2
With control element
Yes
Application in domestic- and commercial area permitted
Yes
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Supporting protocol for TCP/IP
No
Supporting protocol for LON
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for Modbus
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
Supporting protocol for KNX
No
Supporting protocol for DeviceNet
No
Max. output voltage
480V
Supporting protocol for CAN
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFINET IO
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for BACnet
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Number of digital outputs
0
Number of HW-interfaces RS-232
0
Relative symmetric net frequency tolerance
5%
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-422
0
Supporting protocol for PROFIsafe
No
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces other
0
Number of HW-interfaces USB
0
Supporting protocol for Foundation Fieldbus
No
Number of HW-interfaces parallel
0
Number of digital inputs
3
Supporting protocol for DeviceNet Safety
No
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
No
Type of converter
U converter
4-quadrant operation possible
No
Height
1000mm
Degree of protection (IP)
IP55
Width
362mm
Depth
364mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV212WD55N4
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains frequency
50/60 Hz
Mains voltage
380 .. 480V
Number of phases input
3
Nominal output current I2N
116A
Max. output at quadratic load at rated output voltage
55kW
Max. output frequency
200Hz
Number of analogue outputs
1
Relative symmetric net voltage tolerance
10%
Application in industrial area permitted
Number of phases output
3
Max. output at linear load at rated output voltage
55kW
Number of analogue inputs
2
With control element
Application in domestic- and commercial area permitted
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
Supporting protocol for LON
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for KNX
Supporting protocol for DeviceNet
Max. output voltage
480V
Supporting protocol for CAN
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFINET IO
Supporting protocol for EtherNet/IP
Supporting protocol for INTERBUS-Safety
Supporting protocol for BACnet
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Number of digital outputs
0
Number of HW-interfaces RS-232
0
Relative symmetric net frequency tolerance
5%
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-422
0
Supporting protocol for PROFIsafe
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces other
0
Number of HW-interfaces USB
0
Supporting protocol for Foundation Fieldbus
Number of HW-interfaces parallel
0
Number of digital inputs
3
Supporting protocol for DeviceNet Safety
With optical interface
With PC connection
Integrated breaking resistance
Type of converter
U converter
4-quadrant operation possible
Height
1000mm
Degree of protection (IP)
IP55
Width
362mm
Depth
364mm
From same serie