![Main Product Image](https://assets.aleta.hr/415x415/72e4a084-1754-440d-b177-68607697c93e.webp)
![Main Product Image](https://assets.aleta.hr/415x415/72e4a084-1754-440d-b177-68607697c93e.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 - 480V
Max. output voltage
480V
Max. output at linear load at rated output voltage
37kW
Max. output at quadratic load at rated output voltage
37kW
Number of phases output
3
Max. output frequency
200Hz
Mains frequency
50/60 Hz
Relative symmetric net voltage tolerance
10%
Number of analogue inputs
2
Number of analogue outputs
1
Number of phases input
3
Relative symmetric net frequency tolerance
5%
Nominal output current I2N
79A
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
No
4-quadrant operation possible
No
Type of converter
U converter
Degree of protection (IP)
IP55
Height
880mm
Width
284mm
Depth
343mm
Number of digital outputs
0
Number of digital inputs
3
With control element
Yes
Application in industrial area permitted
Yes
Supporting protocol for PROFIBUS
No
Application in domestic- and commercial area permitted
Yes
Supporting protocol for TCP/IP
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for SUCONET
No
Supporting protocol for Modbus
Yes
Supporting protocol for DeviceNet
No
Supporting protocol for Data-Highway
No
Supporting protocol for LON
Yes
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for BACnet
No
Supporting protocol for SafetyBUS p
No
Number of interfaces PROFINET
0
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces other
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV212WD37N4
![Main Product Image](https://assets.aleta.hr/300x300/a50e91da-c5f0-455c-b83f-14ced0fae973_optimized.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 .. 480V
Max. output voltage
480V
Max. output at linear load at rated output voltage
37kW
Max. output at quadratic load at rated output voltage
37kW
Number of phases output
3
Max. output frequency
200Hz
Mains frequency
50/60 Hz
Relative symmetric net voltage tolerance
10%
Number of analogue inputs
2
Number of analogue outputs
1
Number of phases input
3
Relative symmetric net frequency tolerance
5%
Nominal output current I2N
79A
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP55
Height
880mm
Width
284mm
Depth
343mm
Number of digital outputs
0
Number of digital inputs
3
With control element
Application in industrial area permitted
Supporting protocol for PROFIBUS
Application in domestic- and commercial area permitted
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for KNX
Supporting protocol for SUCONET
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for BACnet
Supporting protocol for SafetyBUS p
Number of interfaces PROFINET
0
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces other
0
From same serie