Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases output
3
Max. output at linear load at rated output voltage
11kW
Mains voltage
380 - 480V
Max. output voltage
480V
Max. output at quadratic load at rated output voltage
11kW
Max. output frequency
200Hz
Number of phases input
3
Number of analogue outputs
1
Mains frequency
50/60 Hz
Number of digital outputs
0
Number of analogue inputs
2
Relative symmetric net voltage tolerance
10%
Application in industrial area permitted
Yes
With control element
Yes
Relative symmetric net frequency tolerance
5%
Supporting protocol for TCP/IP
No
Number of digital inputs
3
Supporting protocol for PROFIBUS
No
Nominal output current I2N
22.5A
Supporting protocol for Modbus
Yes
Application in domestic- and commercial area permitted
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for DeviceNet
No
Supporting protocol for KNX
No
Supporting protocol for CAN
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for ASI
No
Supporting protocol for PROFINET IO
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Data-Highway
No
Supporting protocol for SERCOS
No
Supporting protocol for LON
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SafetyBUS p
No
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
No
4-quadrant operation possible
No
Type of converter
U converter
Degree of protection (IP)
IP55
Height
560mm
Width
290mm
Depth
315mm
Supporting protocol for BACnet
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces RS-422
0
Number of HW-interfaces other
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV212WD11N4C
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases output
3
Max. output at linear load at rated output voltage
11kW
Mains voltage
380 .. 480V
Max. output voltage
480V
Max. output at quadratic load at rated output voltage
11kW
Max. output frequency
200Hz
Number of phases input
3
Number of analogue outputs
1
Mains frequency
50/60 Hz
Number of digital outputs
0
Number of analogue inputs
2
Relative symmetric net voltage tolerance
10%
Application in industrial area permitted
With control element
Relative symmetric net frequency tolerance
5%
Supporting protocol for TCP/IP
Number of digital inputs
3
Supporting protocol for PROFIBUS
Nominal output current I2N
22.5A
Supporting protocol for Modbus
Application in domestic- and commercial area permitted
Supporting protocol for INTERBUS
Supporting protocol for DeviceNet
Supporting protocol for KNX
Supporting protocol for CAN
Supporting protocol for SUCONET
Supporting protocol for PROFINET CBA
Supporting protocol for ASI
Supporting protocol for PROFINET IO
Supporting protocol for EtherNet/IP
Supporting protocol for Data-Highway
Supporting protocol for SERCOS
Supporting protocol for LON
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP55
Height
560mm
Width
290mm
Depth
315mm
Supporting protocol for BACnet
Supporting protocol for other bus systems
Number of HW-interfaces RS-422
0
Number of HW-interfaces other
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
From same serie
We use cookies to enhance your experience.