![Main Product Image](https://assets.aleta.hr/415x415/8a105108-d08c-4c99-9d38-edfe9144c053.webp)
![Main Product Image](https://assets.aleta.hr/415x415/8a105108-d08c-4c99-9d38-edfe9144c053.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 - 480V
Number of phases input
3
Mains frequency
50/60 Hz
Relative symmetric net voltage tolerance
10%
Max. output frequency
200Hz
Max. output at linear load at rated output voltage
7.5kW
Number of phases output
3
Nominal output current I2N
16A
With control element
Yes
Max. output at quadratic load at rated output voltage
7.5kW
Max. output voltage
480V
Number of analogue inputs
2
Number of digital outputs
0
Supporting protocol for INTERBUS
No
Number of analogue outputs
1
Supporting protocol for TCP/IP
No
Relative symmetric net frequency tolerance
5%
Application in domestic- and commercial area permitted
Yes
Supporting protocol for ASI
No
Supporting protocol for LON
Yes
Supporting protocol for PROFINET IO
No
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
Yes
Supporting protocol for PROFINET CBA
No
Application in industrial area permitted
Yes
Supporting protocol for CAN
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
No
Supporting protocol for PROFIBUS
No
Number of digital inputs
3
Supporting protocol for KNX
No
With optical interface
No
With PC connection
Yes
4-quadrant operation possible
No
Integrated breaking resistance
No
Degree of protection (IP)
IP21
Type of converter
U converter
Height
232mm
Width
180mm
Depth
170mm
Supporting protocol for BACnet
No
Supporting protocol for other bus systems
Yes
Supporting protocol for INTERBUS-Safety
No
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Supporting protocol for SERCOS
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFIsafe
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces serial TTY
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV212HU75N4
![Main Product Image](https://assets.aleta.hr/300x300/9c1cefd1-7890-42fc-b293-72637fdcbefa_optimized.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 .. 480V
Number of phases input
3
Mains frequency
50/60 Hz
Relative symmetric net voltage tolerance
10%
Max. output frequency
200Hz
Max. output at linear load at rated output voltage
7.5kW
Number of phases output
3
Nominal output current I2N
16A
With control element
Max. output at quadratic load at rated output voltage
7.5kW
Max. output voltage
480V
Number of analogue inputs
2
Number of digital outputs
0
Supporting protocol for INTERBUS
Number of analogue outputs
1
Supporting protocol for TCP/IP
Relative symmetric net frequency tolerance
5%
Application in domestic- and commercial area permitted
Supporting protocol for ASI
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for PROFINET CBA
Application in industrial area permitted
Supporting protocol for CAN
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for PROFIBUS
Number of digital inputs
3
Supporting protocol for KNX
With optical interface
With PC connection
4-quadrant operation possible
Integrated breaking resistance
Degree of protection (IP)
IP21
Type of converter
U converter
Height
232mm
Width
180mm
Depth
170mm
Supporting protocol for BACnet
Supporting protocol for other bus systems
Supporting protocol for INTERBUS-Safety
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for EtherNet/IP
Supporting protocol for PROFIsafe
Supporting protocol for Foundation Fieldbus
Supporting protocol for SafetyBUS p
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces serial TTY
0